文献速递骨肌儿科影像DR

基于深度学习混合GP与改良TW法骨龄评估的临床验证

Clinical Validation of a Deep Learning-Based Hybrid (Greulich-Pyle and Modified Tanner-Whitehouse) Method for Bone Age Assessment.
PubMed 文献 · Korean J Radiol · 2021-10-01

本研究在单中心102例手部X线片上外部验证了一种基于深度学习的混合Greulich-Pyle与改良Tanner-Whitehouse骨龄评估模型。AI与专家参考标准的平均绝对差为0.39年(95%CI 0.33-0.45年),两位放射科医生借助AI后平均阅读时间由54.29秒降至35.37秒(P<0.001),观察者间ICC由0.945升至0.990。

要点

  • AI骨龄与专家参考标准平均绝对差0.39年,准确性可接受。
  • AI辅助使放射科医生平均阅读时间从54.29秒降至35.37秒。
  • AI辅助使两位阅片医生间ICC由0.945提高至0.990。

核心结论

  • 所提出的AI模型骨龄评估准确,与专家参考标准无显著差异。
  • AI辅助可缩短阅片时间并提高观察者间可靠性。

研究设计与样本

  • 单中心外部验证研究,纳入102例手部X线片(男51例、女51例,平均年龄10.95±2.37岁)。
  • 深度学习模型在多种族开放数据集上训练。
  • 由三位人类专家依据GP图谱评估骨龄建立参考标准。
  • 两位研究放射科医生分别在有无AI辅助下阅片,记录阅读时间。
  • 采用配对t检验比较阅读时间,用ICC评估两位医生间可靠性。

诊断标准与关键数值

  • AI骨龄与参考标准平均绝对差0.39年(95%CI 0.33-0.45年)。
  • 专家与AI评估骨龄分别为11.39±2.74岁与11.35±2.76岁,差异无统计学意义(P=0.31)。
  • AI辅助下两位医生间ICC由0.945升至0.990。

临床应用与阅片要点

  • AI可用于手部X线骨龄评估的辅助,减少阅片时间。
  • AI辅助有助于提高不同阅片者间骨龄评估的一致性。

局限性

  • 单中心外部验证,样本量102例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the accuracy and clinical efficacy of a hybrid Greulich-Pyle (GP) and modified Tanner-Whitehouse (TW) artificial intelligence (AI) model for bone age assessment.

MATERIALS AND METHODS: A deep learning-based model was trained on an open dataset of multiple ethnicities. A total of 102 hand radiographs (51 male and 51 female; mean age ± standard deviation = 10.95 ± 2.37 years) from a single institution were selected for external validation. Three human experts performed bone age assessments based on the GP atlas to develop a reference standard. Two study radiologists performed bone age assessments with and without AI model assistance in two separate sessions, for which the reading time was recorded. The performance of the AI software was assessed by comparing the mean absolute difference between the AI-calculated bone age and the reference standard. The reading time was compared between reading with and without AI using a paired t test. Furthermore, the reliability between the two study radiologists' bone age assessments was assessed using intraclass correlation coefficients (ICCs), and the results were compared between reading with and without AI.

RESULTS: The bone ages assessed by the experts and the AI model were not significantly different (11.39 ± 2.74 years and 11.35 ± 2.76 years, respectively, p = 0.31). The mean absolute difference was 0.39 years (95% confidence interval, 0.33-0.45 years) between the automated AI assessment and the reference standard. The mean reading time of the two study radiologists was reduced from 54.29 to 35.37 seconds with AI model assistance (p < 0.001). The ICC of the two study radiologists slightly increased with AI model assistance (from 0.945 to 0.990).

CONCLUSION: The proposed AI model was accurate for assessing bone age. Furthermore, this model appeared to enhance the clinical efficacy by reducing the reading time and improving the inter-observer reliability.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Lee KC, Lee KH, Kang CH, et al. Clinical Validation of a Deep Learning-Based Hybrid (Greulich-Pyle and Modified Tanner-Whitehouse) Method for Bone Age Assessment. Korean J Radiol. 2021. PMID: 34668353. doi:10.3348/kjr.2020.1468

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。