多发性硬化幕下病灶:阅片者内与阅片者间变异与3D卷积神经网络全自动分割的对比
本研究基于1809例患者、156台不同扫描仪的MRI数据训练3D卷积神经网络,用于多发性硬化幕上及幕下病灶分割。三位经验丰富的阅片者手工标注123例MS患者数据。结果显示幕下病灶阅片者间敏感度仅62%,低于幕上病灶的80%;CNN对幕下病灶敏感度0.93,与经验阅片者检测性能相当,且对重复扫描更稳健。
要点
- 幕下MS病灶人工判读一致性明显低于幕上病灶,阅片时需警惕漏诊。
- CNN对幕下病灶敏感度0.93,与经验阅片者相当,且重复扫描更稳健。
- 使用T1作为额外输入并专门训练幕下病灶可显著提升CNN性能。
关键影像表现/征象
- 幕下多发性硬化病灶的阅片者间敏感度为62%,低于幕上病灶的80%。
- CNN对幕上病灶的阅片者内、同扫描仪敏感度为0.97(R1=0.90,R2=0.84)。
- CNN对幕下病灶的敏感度为0.93(R1=0.61,R2=0.73)。
临床应用与阅片要点
- 幕下MS病灶人工判读一致性较低,报告时应注意避免漏诊。
- CNN可作为辅助工具提高幕下病灶检出的一致性。
- 重复扫描时CNN对幕下病灶的检测更稳健,可减少随访差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Automated quantification of infratentorial multiple sclerosis lesions on magnetic resonance imaging is clinically relevant but challenging. To overcome some of these problems, we propose a fully automated lesion segmentation algorithm using 3D convolutional neural networks (CNNs).
METHODS: The CNN was trained on a FLAIR image alone or on FLAIR and T1-weighted images from 1809 patients acquired on 156 different scanners. An additional training using an extra class for infratentorial lesions was implemented. Three experienced raters manually annotated three datasets from 123 MS patients from different scanners.
RESULTS: The inter-rater sensitivity (SEN) was 80% for supratentorial lesions but only 62% for infratentorial lesions. There was no statistically significant difference between the inter-rater SEN and the SEN of the CNN with respect to the raters. For supratentorial lesions, the CNN featured an intra-rater intra-scanner SEN of 0.97 (R1 = 0.90, R2 = 0.84) and for infratentorial lesion a SEN of 0.93 (R1 = 0.61, R2 = 0.73).
CONCLUSION: The performance of the CNN improved significantly for infratentorial lesions when specifically trained on infratentorial lesions using a T1 image as an additional input and matches the detection performance of experienced raters. Furthermore, for infratentorial lesions the CNN was more robust against repeated scans than experienced raters.
KEY POINTS: • A 3D convolutional neural network was trained on MRI data from 1809 patients (156 different scanners) for the quantification of supratentorial and infratentorial multiple sclerosis lesions. • Inter-rater variability was higher for infratentorial lesions than for supratentorial lesions. The performance of the 3D convolutional neural network (CNN) improved significantly for infratentorial lesions when specifically trained on infratentorial lesions using a T1 image as an additional input. • The detection performance of the CNN matches the detection performance of experienced raters.
引用
- Krüger J, Ostwaldt AC, Spies L, et al. Infratentorial lesions in multiple sclerosis patients: intra- and inter-rater variability in comparison to a fully automated segmentation using 3D convolutional neural networks. Eur Radiol. 2021. PMID: 34643779. doi:10.1007/s00330-021-08329-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。