深度学习重建用于儿童低剂量CT:技术原理、图像特征与临床应用
本文综述了深度学习重建(DLR)在儿童低剂量CT中的技术原理、图像特征及临床可行性,指出DLR通过卷积神经网络可降低图像噪声、提升空间分辨率并保留良好噪声纹理,从而在保证诊断图像质量的同时显著降低辐射剂量。
要点
- DLR可在低剂量儿童CT中显著降低辐射剂量同时保持诊断质量
- DLR克服了FBP噪声增加和IR噪声纹理退化、低对比度检测性下降的局限
- DLR重建时间短,适合临床常规使用
关键影像表现/征象
- DLR通过卷积神经网络降低图像噪声、提高空间分辨率并保留良好噪声纹理
- 低剂量CT经FBP重建时图像噪声严重增加,IR可部分解决噪声与剂量权衡但噪声纹理和低对比度检测性仍下降
- DLR利用低剂量训练和高剂量教学图像数据迭代优化网络参数以区分真实衰减与噪声
临床应用与阅片要点
- 在儿童CT中应用DLR可在低剂量条件下获得诊断质量图像,有助于降低辐射风险
- DLR重建时间短,适合临床工作流程
- 需经过网络泛化性验证后使用DLR引擎
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Optimizing the CT acquisition parameters to obtain diagnostic image quality at the lowest possible radiation dose is crucial in the radiosensitive pediatric population. The image quality of low-dose CT can be severely degraded by increased image noise with filtered back projection (FBP) reconstruction. Iterative reconstruction (IR) techniques partially resolve the trade-off relationship between noise and radiation dose but still suffer from degraded noise texture and low-contrast detectability at considerably low-dose settings. Furthermore, sophisticated model-based IR usually requires a long reconstruction time, which restricts its clinical usability. With recent advances in artificial intelligence technology, deep learning-based reconstruction (DLR) has been introduced to overcome the limitations of the FBP and IR approaches and is currently available clinically. DLR incorporates convolutional neural networks-which comprise multiple layers of mathematical equations-into the image reconstruction process to reduce image noise, improve spatial resolution, and preserve preferable noise texture in the CT images. For DLR development, numerous network parameters are iteratively optimized through an extensive learning process to discriminate true attenuation from noise by using low-dose training and high-dose teaching image data. After rigorous validations of network generalizability, the DLR engine can be used to generate high-quality images from low-dose projection data in a short reconstruction time in a clinical environment. Application of the DLR technique allows substantial dose reduction in pediatric CT performed for various clinical indications while preserving the diagnostic image quality. The authors present an overview of the basic concept, technical principles, and image characteristics of DLR and its clinical feasibility for low-dose pediatric CT. ©RSNA, 2021.
引用
- Nagayama Y, Sakabe D, Goto M, et al. Deep Learning-based Reconstruction for Lower-Dose Pediatric CT: Technical Principles, Image Characteristics, and Clinical Implementations. Radiographics. 2021. PMID: 34597178. doi:10.1148/rg.2021210105
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。