儿童胃肠透视检查成像方案、辐射剂量与图像质量的多中心协调研究
该多中心研究回顾性收集五个儿童放射科超过2400例胃肠透视检查(对比灌肠、排尿性膀胱尿道造影、上消化道检查)的方案与剂量数据,并分析临床和体模图像质量。结果显示中心间患者剂量差异大,相似透视时间下可达5倍,且图像质量未随剂量增加而改善,研究提出了基于年龄的诊断参考水平。
要点
- 儿童胃肠透视检查中心间剂量差异大,相似透视时间下可达5倍。
- 增加辐射剂量未显著改善对比度、空间分辨率或噪声。
- 建议按检查类型采用基于年龄的剂量面积乘积和透视时间诊断参考水平。
关键影像表现/征象
- 五个科室的成像方案在透视剂量调节曲线和附加滤过方面存在重大差异。
- 体模和患者图像质量分析显示,增加辐射剂量时对比度、空间分辨率或噪声无显著改善。
诊断标准与关键数值
- 提出了按检查类型基于年龄的诊断参考水平,使用剂量面积乘积和透视时间。
- 相似透视时间下患者剂量中心间差异可达5倍。
临床应用与阅片要点
- 日常阅片和报告中应关注本机构儿童胃肠透视检查的剂量参数,对照提出的基于年龄的诊断参考水平进行优化。
- 注意附加滤过和透视剂量调节曲线的设置差异,避免不必要的剂量增加而不改善图像质量。
局限性
- 回顾性研究设计。
- 仅纳入五个中心,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Paediatric gastrointestinal fluoroscopy examinations can impart varying amounts of radiation for the same patient size and exam type.
OBJECTIVE: To investigate the variability of imaging protocol, radiation dose and image quality in paediatric fluoroscopy examinations in order to provide recommendations for the harmonisation and optimisation of local practices.
MATERIALS AND METHODS: Five paediatric radiology departments performing fluoroscopically-guided contrast enema, micturating cystourethrography and upper gastrointestinal tract examinations participated in this study. Information on imaging protocols and radiation doses was retrospectively collected for more than 2,400 examinations. Image quality was analysed on clinical and phantom images.
RESULTS: Patient doses showed great variability among centers with up to a factor of 5 for similar fluoroscopy times. The five departments had imaging protocols with major differences in fluoroscopy dose regulation curves and additional filtration. Image quality analysis on phantoms and patients images showed no major improvement in contrast, spatial resolution or noise when increasing the radiation dose. Age-based diagnostic reference levels using both dose area product and fluoroscopy time were proposed per procedure type.
CONCLUSION: Disparities between centers and no correlation of radiation dose with image quality criteria create margins for optimisation. These results highlight the need for guidelines on fluoroscopy image quality and dose reference levels in paediatric gastrointestinal examinations to harmonise practices and optimise patient dose.
引用
- Forbes A, Geryes BH, Hornbeck A, et al. Harmonisation of imaging protocols, radiation doses and image quality in gastrointestinal fluoroscopy examinations - multicentre study. Pediatr Radiol. 2021. PMID: 34657168. doi:10.1007/s00247-021-05194-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。