透视与超低剂量CT透视引导腰椎硬膜外类固醇注射的辐射剂量比较

Radiation dose of fluoroscopy-guided versus ultralow-dose CT-fluoroscopy-guided lumbar spine epidural steroid injections.
PubMed 文献 · Skeletal Radiol · 2021-10-06

该回顾性研究比较了透视引导与超低剂量CT透视引导下腰椎硬膜外类固醇注射的辐射剂量。结果显示超低剂量CT透视组有效剂量显著低于透视组(0.15 mSv vs 0.30 mSv,p<0.001),且两组术后即刻疼痛缓解无显著差异。超低剂量CT透视技术可降低辐射剂量。

要点

  • 超低剂量CT透视引导腰椎硬膜外注射的有效剂量显著低于常规透视引导。
  • 两组术后即刻疼痛缓解无统计学显著差异。
  • 超低剂量CT透视技术省略了计划CT扫描,并优化了辐射剂量参数。

局限性

  • 回顾性研究设计。
  • 两组样本量不一致且非同期。
  • 超低剂量CT透视组年龄较大,透视组培训医师参与更多。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Compare radiation dose of lumbar spine epidural steroid injections (ESIs) performed under fluoroscopy guidance and ultralow-dose CT-fluoroscopy guidance.

MATERIALS AND METHODS: Retrospective review of consecutive lumbar ESIs performed using fluoroscopy, between May 2017 and April 2019, and using ultralow-dose CT-fluoroscopy, between August 2019 and February 2021, was performed. Ultralow-dose CT-fluoroscopy technique omits a planning CT scan, utilizes CT-fluoroscopy, and minimizes radiation dose parameters. Patient characteristics (age, sex, height, weight, body mass index (BMI)), procedural characteristics (anatomic level, type of ESI, procedure time, pain reduction, complications, trainee participation), and radiation dose were compared. Chi-square tests and two-sample t-tests were performed for statistical analysis.

RESULTS: One hundred and forty-seven patients (mean age 55.8 ± 16.7; 85 women) underwent ESIs using fluoroscopy. Sixty-six patients (mean age 60.9 ± 16.7; 33 women) underwent ESIs using ultralow-dose CT-fluoroscopy. The effective dose for the fluoroscopy group was 0.30 mSv ± 0.34, compared to 0.15 mSV ± 0.11 for ultralow-dose CT-fluoroscopy (p < 0.001). The average age in the CT-fluoroscopy group was older (p = 0.04), and there was more trainee participation in the fluoroscopy group (p < 0.001); otherwise there was no statistically significant difference in patient or procedural characteristics between the conventional fluoroscopy group and the ultralow-dose CT-fluoroscopy group. There was no statistically significant difference in immediate post-procedure pain reduction between the groups (p = 0.16). Four intrathecal injections occurred only in the fluoroscopy group, though this difference was not significant (p = 0.18).

CONCLUSION: Ultralow-dose CT-fluoroscopy technique for image-guided lumbar spine ESIs can lower radiation dose compared to fluoroscopy-guided technique.

来源:Skeletal Radiol,查看原文。版权归原作者所有。