类风湿关节炎肩关节超声:马格里布风湿病学家共识定义下的信度研究
本研究评估7名操作者对10例确诊类风湿关节炎伴肩痛患者肩关节超声检查的观察者内和观察者间信度,采用OMERACT定义和EULAR肌骨放射学技术指南预设部位。结果显示,肱二头肌长头腱腱鞘炎检测信度较好,而肩胛下肌、后隐窝和腋隐窝的滑膜炎信度中等至差。
要点
- 肱二头肌长头腱腱鞘炎超声检测信度较好,观察者间PD信号κ=0.78。
- 肩胛下肌和后隐窝灰阶滑膜炎观察者内信度好(κ=0.77和0.73)。
- 腋隐窝、肩胛下肌和后隐窝积液及滑膜炎观察者间信度差。
关键影像表现/征象
- 灰阶滑膜炎在肩胛下肌和后隐窝观察者内信度好(κ=0.77和0.73)。
- 肱二头肌长头腱灰阶滑膜炎和积液观察者内信度中等(κ=0.53和0.40)。
- 后隐窝和肩胛下肌隐窝积液观察者内信度中等(κ=0.56和0.60)。
- 腋隐窝灰阶和能量多普勒滑膜炎观察者内信度中等(κ=0.58和0.49)。
- 观察者间信度:肱二头肌长头腱能量多普勒信号好(κ=0.78),灰阶滑膜炎中等(κ=0.54);肩胛下肌、后隐窝和腋隐窝积液及灰阶滑膜炎差,能量多普勒信号极差。
临床应用与阅片要点
- 日常阅片可优先关注肱二头肌长头腱腱鞘炎,其超声检测信度较好。
- 评估肩胛下肌、后隐窝和腋隐窝滑膜炎时需注意信度中等至差,建议标准化扫查部位和设置。
局限性
- 样本量小(10例患者),操作者数量有限(7名)。
- 仅纳入马格里布风湿病学家,结果外推性受限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The shoulder may be affected in a large portion of patients with rheumatoid arthritis (RA) worldwide. However, this joint does not receive the attention required during follow-up. Indeed, although numerous clinical tests for diagnosis of a painful shoulder are available, differentiating articular from peri-articular lesions may be difficult in daily practice. Fortunately, the precise diagnosis of shoulder pain in RA has benefited from a reliable imaging modality used to detect its exact origin-ultrasonography (US). This study was aimed at assessing the intra- and inter-observer reliability of ultrasonographic findings for patients with established RA with shoulder pain in a patient-based exercise as a clinical challenge among Maghrebian rheumatologist experts in US. A total of 7 operators examined 10 patients in two rounds independently and blindly of each other. Before beginning the session, all of the rheumatologists reached a consensus on sites and US settings by performing a brief exercise on a normal shoulder. Outcome Measures in Rheumatology Clinical Trials (OMERACT) definitions of US-detected pathologies were used. Each patient underwent US scanning of the painful shoulder in predefined sites based on US technical guidelines of the European Society of Musculoskeletal Radiology: long head of biceps (LHB), subscapularis recess, posterior recess and axillary recess. The presence of subdeltoid or subcoracoid bursitis or full rupture of the suprasupinatus was identified if present. Intra- and inter-observer reliability measures were calculated using the κ coefficient. Intra-observer reliability was good for gray-scale (GS) synovitis in subscapularis and posterior recesses (κ = 0.77 and 0.73, respectively). It was moderate in the presence of GS synovitis and effusion in LHB (κ =0.53 and 0.40, respectively), posterior and subscapularis recess effusion (κ = 0.56 and 0.60, respectively) and GS and power Doppler (PD) synovitis in axillary recesses (κ = 0.58 and 0.49, respectively). Inter-observer reliability was good for PD for LHB signals (κ = 0.78). It was moderate for GS for LHB synovitis (κ = 0.54). Inter-observer agreement was poor for effusion and GS synovitis for subscapularis, posterior and axillary recesses, and very poor for PD signals in these recesses. US was a reliable imaging tool for detecting tenosynovitis in the LHB. However, reliability was moderate to poor in detecting synovitis in subscapularis, posterior and axillary recesses. These findings could be optimized by standardization of sites to assess.
引用
- Abdelghani KB, Miladi S, Mahmoud I, et al. Ultrasonography of Shoulder in Rheumatoid Arthritis: A Reliability Exercise Using Consensual Definitions among Maghrebian Rheumatologists. Ultrasound Med Biol. 2021. PMID: 34600768. doi:10.1016/j.ultrasmedbio.2021.08.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。