乳腺CT最大密度投影重建独立诊断乳腺病变的性能
回顾性纳入160例接受乳腺CT的女性(80例有已知乳腺影像发现,80例无发现,按年龄和纤维腺体组织量匹配),由2名有B-CT经验的放射科医生在3个平面15mm MIP重建上评估病变和BI-RADS分类。读者间寻找病变的一致性为0.86,BI-RADS分类一致性为0.82;对恶性病变的敏感度为88.9%(95%CI 51.75%-99.72%),特异度读者1为99.3%(95%CI 96.4%-100%),读者2为100%(95%CI 97.20%-100.00%)。结论认为MIP重建作为独立方法评估B-CT图像可能有助于缩短阅读时间并保持高诊断性能和信心。
要点
- 15mm MIP三平面重建可独立用于乳腺CT病变检测与BI-RADS分类。
- 致密乳腺组织可能导致漏诊恶性病变,本研究中1/9癌症被两名读者均漏诊。
- 对无病变患者BI-RADS 1分类正确率约91.3%-92.5%,对有病变患者BI-RADS≥2正确率86.3%。
关键影像表现/征象
- 两名读者发现病变(良性或恶性)的读者间一致性为0.86,BI-RADS分类的读者间一致性为0.82。
- 1/9(11.1%)癌症被两名读者均漏诊,归因于致密乳腺组织。
诊断标准与关键数值
- 无可见病变患者中BI-RADS 1正确应用:读者1为73/80(91.3%),读者2为74/80(92.5%)。
- 至少一侧乳腺有病变时BI-RADS 2或更高正确应用:两名读者均为69/80(86.3%)。
- 发现恶性病变的敏感度:两名读者均为88.9%(95%CI 51.75%-99.72%)。
- 发现恶性病变的特异度:读者1为99.3%(95%CI 96.4%-100%),读者2为100%(95%CI 97.20%-100.00%)。
临床应用与阅片要点
- 可将15mm MIP三平面重建作为B-CT的独立阅片方式,以缩短阅读时间。
- 阅片时需注意致密纤维腺体组织可能掩盖恶性病变,对致密乳腺应结合其他重建或序列谨慎评估。
局限性
- 回顾性研究设计。
- 样本量有限,恶性病变仅9个,敏感度置信区间宽。
- 单中心研究,仅纳入有已知影像发现和无发现的患者,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to evaluate the diagnostic performance of the maximum intensity projection (MIP) reformations of breast computed tomography (B-CT) images as a stand-alone method for the detection and characterization of breast imaging findings.
MATERIALS AND METHODS: A total of 160 women undergoing B-CT between August 2018 and December 2020 were retrospectively included; 80 patients with known breast imaging findings were matched with 80 patients without imaging findings according to age and amount of fibroglandular tissue (FGT). A total of 71 benign and 9 malignant lesions were included. Images were evaluated using 15-mm MIP in 3 planes by 2 radiologists with experience in B-CT. The presence of lesions and FGT were evaluated, using the BI-RADS classification. Interreader agreement and descriptive statistics were calculated.
RESULTS: The interreader agreement of the 2 readers for finding a lesion (benign or malignant) was 0.86 and for rating according to BI-RADS classification was 0.82. One of 9 cancers (11.1%) was missed by both readers due to dense breast tissue. BI-RADS 1 was correctly applied to 73 of 80 patients (91.3%) by reader 1 and to 74 of 80 patients (92.5%) by reader 2 without recognizable lesions. BI-RADS 2 or higher with a lesion in at least one of the breasts was correctly applied in 69 of 80 patients (86.3%) by both readers. For finding a malignant lesion, sensitivity was 88.9% (95% confidence interval [CI], 51.75%-99.72%) for both readers, and specificity was 99.3% (95% CI, 96.4%-100%) for reader 1 and 100% (95% CI, 97.20%-100.00%) for reader 2.
CONCLUSIONS: Evaluation of B-CT images using the MIP reformations may help to reduce the reading time with high diagnostic performance and confidence.
引用
- Zellweger C, Berger N, Wieler J, et al. Breast Computed Tomography: Diagnostic Performance of the Maximum Intensity Projection Reformations as a Stand-Alone Method for the Detection and Characterization of Breast Findings. Invest Radiol. 2022. PMID: 34610622. doi:10.1097/RLI.0000000000000829
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。