文献速递乳腺乳腺X线

基于乳腺X线的列线图预测可疑钙化恶性风险

A Mammography-Based Nomogram for Prediction of Malignancy in Breast Suspicious Calcification.
PubMed 文献 · Acad Radiol · 2021-10-11

本研究回顾性纳入2017年1月至2021年3月连续乳腺X线检查中123例可疑微钙化病例,恶性率为55.2%。基于绝经状态、微钙化最大径、形态和分布构建列线图,AUC为0.839(95%CI:0.771-0.903),可用于个体化恶性风险分层。

要点

  • 微钙化形态为fine pleomorphic或fine linear/branching、分布为线样或段样提示恶性概率更高。
  • 微钙化最大径≥2 cm及绝经后状态是恶性独立预测因素。
  • 列线图AUC为0.839,可辅助BI-RADS评估中的风险分层。

关键影像表现/征象

  • 微钙化形态为fine pleomorphic或fine linear or branching时恶性概率更高。
  • 微钙化分布为线性或段样时恶性概率更高。
  • 微钙化最大径≥2 cm与恶性概率升高相关。
  • 绝经后状态与恶性概率升高相关。

诊断标准与关键数值

  • 列线图预测恶性风险的AUC为0.839(95%CI:0.771-0.903)。
  • 多变量分析显示绝经后、微钙化最大径≥2 cm、形态为fine pleomorphic或fine linear or branching、分布为linear或segmental为恶性预测因素。
  • 按微钙化形态、分布、年龄、绝经状态及最大径分组的恶性率差异有统计学意义。

临床应用与阅片要点

  • 阅片时关注微钙化的形态(fine pleomorphic、fine linear/branching)和分布(linear、segmental),这些特征提示恶性风险增高。
  • 测量微钙化最大径,≥2 cm时应在报告中提示风险增加。
  • 结合患者绝经状态,综合评估可疑微钙化的恶性概率,辅助BI-RADS分类决策。

局限性

  • 回顾性研究设计。
  • 单中心样本,样本量123例。
  • 未报告外部验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To establish a predictive nomogram for malignancy risk stratification of micro-calcifications (MCCs) detected on mammography.

MATERIALS AND METHODS: Consecutive mammograms from January 2017 to March 2021 were retrospectively reviewed. Traditional clinical features were recorded and mammographic features were estimated according to the 5th BI-RADS. A nomogram was developed to graphically predict the malignancy risk based on multivariate logistic regression analysis. The discrimination and calibration performance of the prediction model was assessed.

RESULTS: There were 123 cases of suspicious MCCs with final pathological results identified with a malignancy rate of 55.2%. The malignancy rates of subgroups divided according to the morphology and distribution of MCCs, age, menopausal status and the maximum diameter of MCCs were significantly different. Multivariate logistic analysis showed that a menopause status of postmenopausal, maximum diameters of MCCs ≥2 cm, the morphology of MCCs as fine pleomorphic or fine linear or branching, and the distribution of MCCs as linear or segmental were predictive of a higher probability of malignancy. A prediction nomogram was developed based on four risk factors, including menopausal status as well as the maximum diameters, distribution and morphology of the MCCs. The AUC of that nomogram was 0.839 (95%CI:0.771-0.903).

CONCLUSION: In mammography, the morphology, distribution and maximum diameter of MCCs, and the menopausal status are independent predictors of malignant suspicious MCCs and are readily available in the clinical setting. The nomogram developed in this study for individualized malignancy risk stratification of suspicious MCCs shows a reliable discrimination performance.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen L, Duan HY, Tang XM, et al. A Mammography-Based Nomogram for Prediction of Malignancy in Breast Suspicious Calcification. Acad Radiol. 2021. PMID: 34649781. doi:10.1016/j.acra.2021.09.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。