文献速递乳腺甲状腺与浅表US

多参数剪切波弹性成像指标在乳腺良恶性病变中的评估

Evaluation of Multiparametric Shear Wave Elastography Indices in Malignant and Benign Breast Lesions.
PubMed 文献 · Acad Radiol · 2021-10-19

本研究基于496个乳腺肿块病变(467个良性,29个恶性),评估患者及病变相关因素对剪切波弹性成像参数的影响,并计算各参数诊断恶性的截断值。结果显示良性病变的SWE指标与病变边缘、深度和大小相关,Vmax预测恶性的敏感度96.3%、特异度94.7%,为最敏感参数。

要点

  • Vmax截断值6.87 m/s,预测乳腺恶性病变敏感度96.3%、特异度94.7%。
  • 良性病变中SWE指标受病变边缘、深度和大小影响,与年龄和绝经状态无关。
  • BI-RADS 3活检病变均良性,4a中23.5%恶性,4b-4c-5均恶性。

关键影像表现/征象

  • 良性病变中SWE指标与病变边缘、距皮肤深度和病变大小相关(p<0.05)。
  • 良性病变中SWE指标与年龄、绝经状态、病变形状及距乳晕距离无显著相关(p>0.05)。

诊断标准与关键数值

  • 恶性病变截断值:Vmean 3.38 m/s,Vsd 0.81,Vmax 6.87 m/s,Vmin 1.53 m/s。
  • Vmax敏感度96.3%、特异度94.7%,截断值6.87 m/s,准确率94.7%。
  • Vmean截断值3.37 m/s和Vsd截断值0.8,准确率92.5%。
  • BI-RADS 3病变活检均良性(n=35);4a病变23.5%恶性(n=4/17);4b-4c-5病变均恶性(n=25/25)。

临床应用与阅片要点

  • 日常可参考Vmax截断值6.87 m/s辅助鉴别乳腺良恶性肿块。
  • 解读SWE时需考虑病变边缘、深度和大小对硬度测值的影响。
  • BI-RADS 4a病变恶性比例不低,结合SWE参数可提高诊断信心。

局限性

  • 仅纳入肿块型病变,未包括非肿块型病变。
  • 恶性病变样本量较小(29例),结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the shear wave elastography indices (multiparametric SWE) of breast lesions based on patient and lesion dependent features and assess the contribution of different elastographic parameters to radiological diagnosis.

MATERIALS AND METHODS: Effect of patient-dependent (age and menopausal status) and lesion-dependent (distance from the areola, quadrant location, size, depth, margin and shape) factors on SWE parameters (Vmean, Vsd, Vmax, Vmin) in benign breast lesions were assessed. Only mass lesions were included in the study. Sensitivity, specificity, PPV, NPV and cut-off values for each elastography parameter was calculated.

RESULTS: A total of 496 mass lesions of breast were evaluated. 467 of the lesions were benign and 29 were malignant. There was no significant relationship among SWE indices and age, menopausal status, lesion shape and distance to the areola in benign lesions (p>0.05). SWE indices were found to be associated with lesion margin, depth from the skin, and lesion size in benign lesions (p<0.05). All BI-RADS 3 lesions that underwent biopsy were benign (n:35); 23.5% of 4a lesions were malignant (n:4/17) and all 4b-4c-5 lesions were malignant (n:25/25). The cut-off values for malignant lesions were: Vmean 3.38 m/s, Vsd 0.81, Vmax 6.87 m/s, Vmin 1.53 m/s. All SWE parameters were statistically significant in predicting malignancy on ROC analysis, Vmax was the most sensitive (96.3%) and specific (94.7%) parameter. Cut-off values for Vmax was 6.87 m/s with an accuracy rate of 94.7%, and 3.37 m/s for Vmean and 0.8 for Vsd with 92.5% accuracy.

CONCLUSION: The SWE parameters to predict malignancy in breast lesions can be affected by lesion dependent features, whereas no significant effect of patient's age or menopausal status on stiffness of the lesions was observed. Vmax had the highest sensitivity for predicting malignancy.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Tekcan Sanli DE, Yildirim D, Kandemirli SG, et al. Evaluation of Multiparametric Shear Wave Elastography Indices in Malignant and Benign Breast Lesions. Acad Radiol. 2021. PMID: 34674923. doi:10.1016/j.acra.2021.09.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。