深度学习自动分诊乳腺MRI:DENSE试验4581例次分析
基于DENSE试验首轮筛查的4581例极密乳腺MRI,开发深度学习模型区分有无病灶。在恶性病变敏感度100%条件下,模型将90.7%有病灶检查分诊至放射科复核,并排除39.7%无病灶检查,平均AUC为0.83。
要点
- 极密乳腺MRI筛查中,深度学习模型可在不漏诊恶性病变前提下排除近40%无病灶检查。
- 模型以100%敏感度将90.7%有病灶检查分诊至复核,平均AUC为0.83。
- 该分诊方法有望减少放射科医师对正常解剖生理变异MRI的复核工作量。
关键影像表现/征象
- 9162个乳腺中838个至少有一个BI-RADS 2-5病灶,其中77个为恶性,8324个无病灶。
- 模型将90.7%(95%CI:86.7,94.7)有病灶检查判为非正常并分诊至放射科复核。
- 模型排除39.7%(95%CI:30.0,49.4)无病灶检查。
诊断标准与关键数值
- 以恶性病变敏感度100%为条件,评估被排除放射科复核的检查比例。
- 模型区分正常与有病灶乳腺MRI的平均AUC为0.83(95%CI:0.80,0.85)。
- 病灶定义为BI-RADS 2-5类,包括良性及恶性病变。
临床应用与阅片要点
- 可用于极密乳腺MRI筛查中正常解剖生理变异检查的自动分诊,减少放射科复核负荷。
- 模型以100%恶性病变敏感度为分诊前提,阅片时仍需对分诊至复核的检查重点审核。
- 外部验证采用八折轮换,每家医院均作为一次外部测试集,结果具有一定泛化参考价值。
局限性
- 本文为DENSE试验二次分析,非独立前瞻性验证。
- 仅纳入极密乳腺首轮筛查MRI,结论外推至其他人群需谨慎。
- 模型训练与测试均基于8家医院数据,多中心泛化性仍需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Supplemental screening with MRI has proved beneficial in women with extremely dense breasts. Most MRI examinations show normal anatomic and physiologic variation that may not require radiologic review. Thus, ways to triage these normal MRI examinations to reduce radiologist workload are needed. Purpose To determine the feasibility of an automated triaging method using deep learning (DL) to dismiss the highest number of MRI examinations without lesions while still identifying malignant disease. Materials and Methods This secondary analysis of data from the Dense Tissue and Early Breast Neoplasm Screening, or DENSE, trial evaluated breast MRI examinations from the first screening round performed in eight hospitals between December 2011 and January 2016. A DL model was developed to differentiate between breasts with lesions and breasts without lesions. The model was trained to dismiss breasts with normal phenotypical variation and to triage lesions (Breast Imaging Reporting and Data System [BI-RADS] categories 2-5) using eightfold internal-external validation. The model was trained on data from seven hospitals and tested on data from the eighth hospital, alternating such that each hospital was used once as an external test set. Performance was assessed using receiver operating characteristic analysis. At 100% sensitivity for malignant disease, the fraction of examinations dismissed from radiologic review was estimated. Results A total of 4581 MRI examinations of extremely dense breasts from 4581women (mean age, 54.3 years; interquartile range, 51.5-59.8 years) were included. Of the 9162 breasts, 838 had at least one lesion (BI-RADS category 2-5, of which 77 were malignant) and 8324 had no lesions. At 100% sensitivity for malignant lesions, the DL model considered 90.7% (95% CI: 86.7, 94.7) of the MRI examinations with lesions to be nonnormal and triaged them to radiologic review. The DL model dismissed 39.7% (95% CI: 30.0, 49.4) of the MRI examinations without lesions. The DL model had an average area under the receiver operating characteristic curve of 0.83 (95% CI: 0.80, 0.85) in the differentiation between normal breast MRI examinations and MRI examinations with lesions. Conclusion Automated analysis of breast MRI examinations in women with dense breasts dismissed nearly 40% of MRI scans without lesions while not missing any cancers. ClinicalTrials.gov: NCT01315015 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Joe in this issue.
引用
- Verburg E, van Gils CH, van der Velden BHM, et al. Deep Learning for Automated Triaging of 4581 Breast MRI Examinations from the DENSE Trial. Radiology. 2021. PMID: 34609196. doi:10.1148/radiol.2021203960
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。