子宫内膜癌肌层浸润深度评估:骨盆轴位正交与子宫轴位动态增强MRI协议比较
本研究回顾性分析398例子宫内膜癌患者术前MRI,比较骨盆轴位正交增强(OPA CE-MRI)与子宫轴位正交动态增强(OUA DCE-MRI)评估肌层浸润深度的诊断性能,以术后病理为参考标准。结果显示OUA DCE-MRI在检测肌层浸润存在方面AUC显著更高(0.71 vs 0.49,P<0.05),并在无肌层浸润、浅肌层浸润及合并腺肌症/黏膜下肌瘤、宫角肿瘤、前后径≤10mm等亚组中诊断准确性更优。
要点
- 子宫轴位动态增强MRI评估肌层浸润深度的AUC显著优于骨盆轴位增强MRI(0.71 vs 0.49)。
- 对无肌层浸润和浅肌层浸润的鉴别,OUA DCE-MRI准确性更高,尤其在合并腺肌症/肌瘤等困难病例中。
- 深肌层浸润的诊断性能两种协议无显著差异。
诊断标准与关键数值
- 检测肌层浸润存在的AUC:OUA DCE-MRI 0.71 vs OPA CE-MRI 0.49(放射科医师1,P<0.05)。
- 无肌层浸润诊断准确性:OUA DCE-MRI 45.5% vs OPA CE-MRI 0%(医师1)和12.5%(医师2),P值分别为0.045和0.177。
- 浅肌层浸润诊断准确性:OUA DCE-MRI 88.7% vs OPA CE-MRI 86.4%(医师1,P=0.567)和78.8%(医师2,P=0.027)。
- 合并腺肌症/黏膜下肌瘤亚组准确性:OUA DCE-MRI 86.4% vs OPA CE-MRI 71.4%(医师1,P=0.048)和64.3%(医师2,P=0.006)。
- 宫角肿瘤亚组准确性:OUA DCE-MRI 91.2% vs OPA CE-MRI 67.7%(医师1,P=0.018)和88.2% vs 64.5%(医师2,P=0.023)。
局限性
- 回顾性研究设计。
- 单中心研究。
- 两种协议分别应用于不同患者队列,非同一患者自身对照。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To compare the diagnostic performance of orthogonal pelvis-axial (OPA) contrast-enhanced (CE) and orthogonal uterus-axial (OUA) dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) protocols in assessing the depth of myometrial invasion (MI) of endometrial carcinoma (EC).
MATERIALS AND METHODS: Preoperative MRI of 398 consecutive EC patients (197 patients with OPA CE-MRI protocol and 201 patients with OUA DCE-MRI protocol) was analyzed. Two radiologists independently interpreted the depth of MI, with postoperative histopathology as the reference standard. The chi-square test, Fisher's exact test, and receiver operating characteristic curve analysis were used for diagnostic performance comparison.
RESULTS: OUA DCE-MRI showed a significantly larger area under the curve than OPA CE-MRI in detecting the presence of MI for radiologist 1 (0.71 versus 0.49, p < 0.05) but not for radiologist 2 or deep MI (all p > 0.05). Compared to OPA CE-MRI, OUA DCE-MRI significantly improved the diagnostic accuracy of non-MI and superficial MI (radiologist 1: 45.5% versus 0 and 88.7% versus 86.4%, p = 0.045 and 0.567, respectively; radiologist 2: 45.5% versus 12.5% and 88.7% versus 78.8%, p = 0.177 and 0.027, respectively) and of EC with adenomyosis/submucous myomas, cornual tumor, and antero-posterior diameter ≤ 10 mm (radiologist 1: 86.4% versus 71.4%, 91.2% versus 67.7%, and 90.1% versus 81.1%, p = 0.048, 0.018, and 0.081, respectively; radiologist 2: 86.4% versus 64.3%, 88.2% versus 64.5%, and 87.0% versus 71.6%, p = 0.006, 0.023, and 0.019, respectively).
CONCLUSION: The OUA DCE-MRI protocol was superior to the OPA CE-MRI protocol in assessing the depth of MI of EC.
引用
- Ma X, Qiang J, Zhang G, et al. Evaluation of the Depth of Myometrial Invasion of Endometrial Carcinoma: Comparison of Orthogonal Pelvis-axial Contrast-enhanced and Uterus-axial Dynamic Contrast-enhanced MRI Protocols. Acad Radiol. 2021. PMID: 34645571. doi:10.1016/j.acra.2021.09.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。