产前超声联合超微血管成像评估胎盘病理的准确性:前瞻性观察研究
该前瞻性诊断观察研究纳入因胎儿生长受限、子痫前期及其他指征入院行围产期管理的孕妇,在分娩前用超微血管成像(SMI)检测胎盘病理,产后于超声引导定位处取材行显微镜检查对照。结果示SMI可准确检出胎盘梗死及无血管绒毛等病理表现,其中胎儿生长受限组的胎盘梗死准确率最高(阳性预测值100%、敏感度89%、曲线下面积0.945)。
要点
- SMI可在产前显示胎盘低流速血流,用于检出胎盘梗死和无血管绒毛。
- 胎儿生长受限组胎盘梗死的阳性预测值达100%、敏感度89%、AUC 0.945。
- 产前SMI检出胎盘病理可能有助于改善胎盘功能不全病例的围产期管理。
核心结论
- SMI能够准确检出胎盘梗死及无血管绒毛等胎盘病理表现,可能改善胎盘功能不全病例的围产期管理。
研究设计与样本
- 前瞻性诊断观察研究,纳入本中心因围产期管理入院的孕妇,分娩前用SMI行胎盘病理超声检查,产后于超声引导定位处取材行显微镜检查对照。
- 按入院指征分为胎儿生长受限组、子痫前期组及其他指征组,比较产前超声检出胎盘病理的准确性。
关键影像表现/征象
- SMI可显示胎盘低流速血流,用于产前识别胎盘梗死及无血管绒毛等病理改变。
诊断标准与关键数值
- 胎儿生长受限组胎盘梗死:阳性预测值100%、敏感度89%、曲线下面积0.945。
临床应用与阅片要点
- 对胎儿生长受限孕妇可应用SMI重点评估胎盘梗死,产后于超声定位处取材有助于病理对照验证。
- SMI为低流速血流成像方法,判读胎盘无血管区时需结合临床指征综合判断。
局限性
- 单中心前瞻性观察研究,纳入人群为因围产期管理入院的孕妇,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Superb microvascular imaging (SMI) is a new Doppler method that enables the visualization of low-velocity blood flow. The aim of the study described here was to clarify whether SMI can detect prenatal pathological findings in pathologic placentas. In this prospective diagnostic observational study, pregnant women who were admitted to our center for perinatal management were enrolled. Ultrasound examinations to identify placental pathologies using SMI were performed before delivery. After delivery, the placental tissue was clipped for microscopic examination at locations determined under ultrasound guidance. The accuracy of prenatal ultrasound detection of placental pathologies was compared between women who were admitted because of fetal growth restriction (FGR), pre-eclampsia and other indications. The highest accuracy was observed with placental infarction in FGR (positive predictive value = 100%, sensitivity = 89%, area under the curve = 0.945). As a result, it became clear that SMI can accurately detect placental pathologic findings, such as placental infarction and avascular villi. This modality may improve perinatal management in cases of placental dysfunction.
引用
- Furuya N, Hasegawa J, Doi M, et al. Accuracy of Prenatal Ultrasound in Evaluating Placental Pathology Using Superb Microvascular Imaging: A Prospective Observation Study. Ultrasound Med Biol. 2021. PMID: 34642082. doi:10.1016/j.ultrasmedbio.2021.09.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。