三维能量多普勒超声联合VOCAL技术检测前列腺癌的性能特征
该前瞻性研究纳入99例因PSA升高或直肠指检异常转诊行前列腺穿刺活检的男性患者,在活检前采用经直肠三维能量多普勒超声联合VOCAL技术获取血管化指数、血流指数和血管化/血流指数,并与组织病理学结果比较。结果显示3-D-PD-VOCAL可区分恶性与良性病灶,VI和VFI对临床显著前列腺癌的诊断性能优于血流指数,且各参数在外周带的曲线下面积高于移行带。
要点
- VI和VFI对临床显著前列腺癌的诊断性能优于血流指数。
- 各定量血管参数在外周带检测病灶的AUC均高于移行带。
- VI鉴别恶性与良性病灶的截断值为27.4%,VFI为8.6。
核心结论
- 3-D-PD-VOCAL在检测前列腺癌方面初步表现出良好性能。
- VI和VFI对临床显著前列腺癌的诊断性能优于血流指数。
- 需要基于前列腺切除标本的更大样本研究来评估该技术的确切价值。
研究设计与样本
- 前瞻性研究,纳入99例因血清PSA升高或直肠指检异常转诊行前列腺穿刺活检的男性患者。
- 活检前采用经直肠三维能量多普勒超声联合VOCAL技术获取VI、血流指数和VFI定量血管参数。
- 以组织病理学结果为参考标准进行比较。
诊断标准与关键数值
- 3-D-PD-VOCAL区分恶性与良性病灶的截断值:VI为27.4%,血流指数为38.2,VFI为8.6。
- 检测临床显著前列腺癌时,VI的AUC为95%、敏感度86%、特异度87%、准确率87%。
- 检测临床显著前列腺癌时,VFI的AUC为95%、敏感度94%、特异度76%、准确率85%。
临床应用与阅片要点
- 可关注VI和VFI作为定量血管参数在鉴别前列腺良恶性病灶中的辅助价值。
- 解读结果时注意外周带与移行带的诊断性能存在差异,外周带AUC更高。
局限性
- 样本量有限,需更大样本研究验证。
- 参考标准为穿刺活检病理,而非前列腺切除标本。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The purpose of this study was to test the diagnostic performance of 3-D power Doppler ultrasound (3-D-PD) with the virtual organ computer-aided analysis (VOCAL) technique in the detection of prostate cancers (PCa). A total of 99 male patients referred for needle prostate biopsy owing to elevated serum prostate-specific antigen or abnormal direct rectal examination were prospectively included. The transrectal 3-D-PD-VOCAL quantitative vascularity parameters of vascularization index (VI), flow index and vascularization/flow index (VFI) were obtained before biopsy and compared with histopathologic results. We evaluated the predictive values for the detection of clinically significant PCa in the foci from different zones and the discrimination among various cancer grades. 3-D-PD-VOCAL discriminated malignant from benign foci, with cutoff values of 27.4% for VI, 38.2 for flow index and 8.6 for VFI. All parameters had higher areas under the curve in detecting lesions in the peripheral zone than in the transition zone (p < 0.05). VI and VFI had better diagnostic performance in detecting clinically significant PCa than flow index (p < 0.05). The area under the curve, sensitivity, specificity and accuracy in detecting clinically significant PCa were, for the VI and VFI respectively, 95% and 95%, 86% and 94%, 87% and 76%, and 87% and 85%. 3-D-PD-VOCAL initially demonstrated favorable performance in detecting PCa. Further, larger-sample studies based on prostatectomy specimens are needed to evaluate the exact usefulness of the technique.
引用
- Zeng S, Wu S, Chen C, et al. Performance Characteristics of 3-D Power Doppler Ultrasound (3-D-PD) with the Virtual Organ Computer-Aided Analysis (VOCAL) Technique in the Detection of Prostate Cancer. Ultrasound Med Biol. 2021. PMID: 34702643. doi:10.1016/j.ultrasmedbio.2021.09.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。