双层探测器双能CT虚拟平扫衰减值:单次与分次团注方案的比较
本研究回顾性纳入105例行肾脏期双层探测器双能CT的患者,比较单次团注与分次团注方案下虚拟平扫与真实平扫的衰减值一致性。结果显示虚拟平扫在肝、门静脉、脾、肾实质高估真实平扫,肾盂在分次团注组显著高估,且肾实质和肾盂的虚拟平扫衰减值在两种方案间存在差异。
要点
- 虚拟平扫在肝、脾、肾实质及门静脉的衰减值高于真实平扫,报告时需注意。
- 分次团注方案下肾盂虚拟平扫衰减值显著高于单次团注,可能影响肾盂评估。
- 肾实质虚拟平扫衰减值单次团注组高于分次团注组。
局限性
- 回顾性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare virtual unenhanced (VUE) attenuation values and their agreement with true unenhanced (TUE) images in patients who underwent dual-layer detector-based dual-energy computed tomography (dlDECT) with single- vs. split-bolus contrast media protocol.
METHODS: In this HIPAA-compliant, IRB-approved retrospective analysis, a total of 105 patients who underwent nephrographic phase (NP) dlDECT between 07/2018 and 11/2019 were included: 55 patients received single bolus and 50 patients split-bolus examinations. Both scan protocols comprised a TUE and 120-kVp NP acquisition from which VUE images were reconstructed. A radiologist performed ROI-based attenuation measurements of liver parenchyma, main portal vein, aorta, spleen, renal parenchyma, and pelvis on TUE and VUE images. Agreement between TUE and VUE images was determined and compared for both protocols and each anatomic region.
RESULTS: VUE attenuation was significantly higher than TUE attenuation in both cohorts in the liver, portal vein, spleen, and renal parenchyma (p < 0.05), while it was similar in the abdominal aorta in both cohorts (p = 0.05, 0.7522, respectively). VUE attenuation was significantly higher than TUE attenuation in the renal pelvis of the split-bolus cohort (p < 0.05). When comparing VUE images between single- and split-bolus protocols, the renal parenchyma yielded a significantly higher VUE attenuation in the single-bolus cohort (single bolus: 38.8 ± 3.3 HU vs. split bolus: 36.8 ± 3.6 HU; p < 0.05), whereas the split-bolus cohort revealed markedly higher VUE attenuation in the renal pelvis (single bolus: 2.3 ± 10.8 HU vs. split bolus: 92.3 ± 76.8; p < 0.05). Mean intra-patient differences between TUE and VUE images were comparable between single- and split-bolus cohorts (p-range 0.09-0.35) except for the renal parenchyma and pelvis: in the first, the single-bolus cohort yielded a higher VUE attenuation, while in the second, attenuation was significantly higher in the split-bolus cohort (p < 0.05).
CONCLUSION: VUE attenuation overestimated TUE attenuation and differed between split- and single-bolus protocols for the renal parenchyma and pelvis, while all other tissues showed comparable VUE attenuation.