本研究回顾性分析104例因动脉性急性肠缺血手术患者的术前CTA,由2名放射科医生盲法评估血管征象。22例术后48小时内死亡,死亡组肠系膜上动脉分支数显著减少(p=0.006),静脉回流减少(区域1,p=0.04;>2个区域,p=0.01)与早期死亡相关。基于这些征象构建的AAII48评分AUC为0.784,阈值6分时敏感度68%、特异度77%,观察者间ICC为0.81。

要点

  • 肠系膜上动脉分支数≤5是术后48小时死亡的独立预后因素。
  • 静脉回流减少累及区域1或超过2个区域提示早期死亡风险增高。
  • AAII48评分≥6分时,识别术后48小时死亡风险的敏感度68%、特异度77%。

关键影像表现/征象

  • 死亡组肠系膜上动脉分支数量显著减少(p=0.006)。
  • 区域1(结肠右曲、横结肠近半、回肠近端)静脉回流减少与48小时死亡相关(p=0.04)。
  • 超过2个区域静脉回流减少与48小时死亡相关(p=0.01)。

诊断标准与关键数值

  • AAII48评分包含1个保护性临床项目和5个影像学项目,AUC为0.784。
  • 阈值6分时,预测术后48小时死亡的敏感度为68%,特异度为77%。
  • 评分观察者间ICC为0.81(95%CI 0.73–0.87)。

临床应用与阅片要点

  • 阅片时注意计数肠系膜上动脉分支,分支数≤5提示预后不良。
  • 在冠状位重建上评估静脉回流减少的腹部分区,尤其关注区域1及受累区域数量。
  • 可结合AAII48评分辅助识别术后48小时死亡高危患者,便于调整管理策略。

局限性

  • 回顾性单中心设计,样本量有限(104例)。
  • 评分包含临床项目,影像科医生单独使用时需注意。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate vascular features on abdominal Computed-Tomography Angiography (CTA) correlated with 48-h mortality in patients who underwent arterial acute intestinal ischemia (AAII) surgery. The secondary objective was to create a prognostic score on the 48-h mortality after surgery, based on the most relevant signs.

METHOD: We included 104 patients who underwent surgery for acute mesenteric ischemia. 2 radiologists retrospectively blind reviewed the preoperative CTA scans. They used a standardized analysis grid for the arterial and venous vascular signs described in angiography. When signs were present, the affected abdominal quadrant was specified in coronal reconstruction. Each sign was analyzed for 48-h mortality on CTA. A score based on signs correlated with early mortality was developed and evaluated by ROC curve analysis.

RESULTS: 22 patients died within 48 h. The number of superior mesenteric artery (SMA) branches was significantly reduced in deceased patients (p = 0.006). Other prognostic factors associated with 48-h mortality were decreased venous return in area number 1 corresponding to right colic flexure, proximal half of the transverse colon, proximal ileum (p = 0.04) and decreased venous return in more than 2 zones (p = 0.01). The weighted AAII48 score included 1 protective clinical item and 5 radiological items. The area under the ROC curve was 0.784 with, for a 6-point threshold value, a sensitivity of 68% and a specificity of 77%. The intraclass correlation coefficient for interobserver reproducibility of the score was 0.81 [95% CI 0.73; 0.87].

CONCLUSION: Three vascular signs on CTA were found to be prognostic factors for early mortality: SMA branches number ≤ 5 (p = 0.006), decreased venous return in area 1 (p = 0.04), and > 2 areas of decreased venous return (p = 0.01). They were incorporated into the AAII48 score. This score could help to identify patients at risk and to adapt subsequent management.