文献速递腹部MR

1.5T屏气三维MRCP结合深度学习降噪与常规呼吸触发技术的比较

Breath-hold 3D magnetic resonance cholangiopancreatography at 1.5 T using a deep learning-based noise-reduction approach: Comparison with the conventional respiratory-triggered technique.
PubMed 文献 · Eur J Radiol · 2021-10-05

结果显示屏气降噪MRCP的定性评分与呼吸触发MRCP相当或更高,SNR和CNR显著更高,表明深度学习降噪使屏气快速MRCP在不损失图像质量的前提下临床可行。

要点

  • 屏气降噪MRCP的胆管可见性评分与呼吸触发MRCP相当或更高。
  • 屏气降噪MRCP的SNR和CNR显著高于呼吸触发MRCP。
  • 深度学习降噪使1.5T屏气MRCP快速成像且不损失图像质量。

关键影像表现/征象

  • 定性分析评估近端胆总管、胰胆管汇合部、主胰管远端、胆囊管及左右肝管的可见性,并评估伪影和整体图像质量。
  • 屏气降噪MRCP的定性评分显著高于屏气MRCP(P < 0.02)。
  • 屏气降噪MRCP的定性评分与呼吸触发MRCP相当或更高(P = 0.048-1.000)。

诊断标准与关键数值

  • 屏气降噪MRCP的SNR和CNR显著高于屏气MRCP(P < 0.001)。
  • 屏气降噪MRCP的SNR和CNR显著高于呼吸触发MRCP(P < 0.001和P = 0.001)。
  • 屏气MRCP可在单次屏气中成功完成。

临床应用与阅片要点

  • 屏气降噪MRCP可作为1.5T快速MRCP方案,图像质量不劣于常规呼吸触发MRCP。
  • 深度学习降噪能改善屏气MRCP的胆管可见性和信噪比,有助于报告中对细小胆管结构的评估。

局限性

  • 原文未报告诊断准确性(敏感度、特异度、AUC)及与参考标准的对照。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the image quality of conventional respiratory-triggered 3-dimentional (3D) magnetic resonance cholangiopancreatography (Resp-MRCP) and breath-hold 3D MRCP (BH-MRCP) with and without denoising procedure using deep learning-based reconstruction (dDLR) at 1.5 T.

METHODS: Forty-two patients underwent MRCP at 1.5 T MRI. The following imaging sequences were performed: Resp-MRCP and BH-MRCP. We applied the dDLR method to the BH-MRCP data (BH-dDLR-MRCP). As a qualitative analysis, two radiologists rated the visibility of the proximal common bile duct (CBD), pancreaticobiliary junction, distal main pancreatic duct, cystic duct, and right and left hepatic ducts. Artifacts and overall image quality were also rated. The signal-to-noise ratios (SNRs), contrast ratios, and contrast-to-noise ratios (CNRs) of the CBD images were calculated for quantitative analysis.

RESULTS: BH-MRCP was successfully performed in a single BH. The qualitative and quantitative measurements for BH-dDLR-MRCP were significantly higher than for BH-MRCP (P < 0.02 and P < 0.001, respectively), and the qualitative measurements for BH-dDLR-MRCP were equivalent to or higher than for Resp-MRCP (P = 0.048-1.000). The SNRs and CNRs for BH-dDLR-MRCP were significantly higher than for Resp-MRCP (P < 0.001 and P = 0.001, respectively).

CONCLUSION: dDLR is useful and clinically feasible for BH-MRCP at 1.5 T MRI, and enables rapid imaging without loss of image quality compared to conventional Resp-MRCP.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tajima T, Akai H, Sugawara H, et al. Breath-hold 3D magnetic resonance cholangiopancreatography at 1.5 T using a deep learning-based noise-reduction approach: Comparison with the conventional respiratory-triggered technique. Eur J Radiol. 2021. PMID: 34627106. doi:10.1016/j.ejrad.2021.109994

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。