文献速递腹部US

LR-M标准修订对超声造影LI-RADS诊断效能的影响

Impact of Revision of the LR-M Criteria on the Diagnostic Performance of Contrast-Enhanced Ultrasound LI-RADS.
PubMed 文献 · Ultrasound Med Biol · 2021-09-28

本研究纳入264例有肝细胞癌风险患者的264个结节,按CEUS LI-RADS 2017版分类,分析不同早期廓清标准对LR-M分类的影响。以45秒作为早期廓清标准重新分类后,LR-5诊断HCC的敏感度(65.5% vs. 76.2%,p=0.012)和AUC(0.80 vs. 0.85,p=0.001)提高,LR-M诊断非HCC恶性肿瘤的特异度(71.4% vs. 81.3%,p=0.010)也提高。

要点

  • CEUS LR-5对HCC诊断有效,阳性预测值98.6%。
  • 以45秒为早期廓清标准可提高LR-5诊断HCC的敏感度和AUC。
  • 修订LR-M标准可提高其诊断非HCC恶性肿瘤的特异度。

诊断标准与关键数值

  • LR-5、LR-4和LR-3的阳性预测值分别为98.6%、72.2%和16.7%。
  • LR-M中非HCC恶性肿瘤的阳性预测值为25.0%。
  • 以45秒为早期廓清标准重新分类后,LR-5诊断HCC的敏感度为76.2%(原65.5%,p=0.012),AUC为0.85(原0.80,p=0.001)。
  • 以45秒为早期廓清标准重新分类后,LR-M诊断非HCC恶性肿瘤的特异度为81.3%(原71.4%,p=0.010)。

临床应用与阅片要点

  • 采用45秒作为早期廓清标准可优化LR-5和LR-M的分类效能。
  • 注意LR-M中非HCC恶性肿瘤的阳性预测值较低(25.0%)。

局限性

  • 单中心研究,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study was aimed at revising the LI-RADS M category (LR-M) criteria to improve the diagnostic performance categories LR-5 and LR-M of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) Version 2017. We enrolled 264 patients (264 nodules) with a risk for hepatocellular carcinoma (HCC). The nodules were assigned specific CEUS LI-RADS categories. Washout onset times for all nodules were noted. The diagnostic performance of LR-5 and LR-M was analyzed based on the different early washout criterion for the LR-M category. The positive predictive values in LR-5, LR-4 and LR-3 were 98.6%, 72.2% and 16.7%, respectively, and that for non-HCC malignancies in LR-M was 25.0%. Patients in the LR-M category were reclassified using 45 s as the early washout criterion. LR-5 had higher sensitivity (65.5% vs. 76.2%, p = 0.012) and area under the receiver operating characteristic curve (0.80 vs. 0.85, p = 0.001) for HCC diagnosis after reclassification. LR-M also had higher specificity (71.4% vs. 81.3%, p = 0.010) in diagnosing non-HCC malignancies after reclassification. Our findings suggest CEUS LR-5 is effective for HCC diagnosis. The use of 45 s as the time criterion of early washout for LR-M can improve LR-5 and LR-M performance in the diagnosis of HCC and non-HCC malignancies, respectively.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Ding J, Qin Z, Zhou Y, et al. Impact of Revision of the LR-M Criteria on the Diagnostic Performance of Contrast-Enhanced Ultrasound LI-RADS. Ultrasound Med Biol. 2021. PMID: 34598799. doi:10.1016/j.ultrasmedbio.2021.08.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。