二维剪切波弹性成像肝硬度筛查代偿期进展性慢性肝病高危静脉曲张
本研究纳入661例代偿期进展性慢性肝病患者,评估二维剪切波弹性成像测肝硬度联合血小板计数排除高危静脉曲张的效能。Baveno VI标准(LS<20 kPa且PLT>150×10⁹/L)漏诊率2.1%,但仅节省19.2%内镜;新标准LS<16 kPa且PLT>100×10⁹/L可节省30.4-34.6%内镜,漏诊率0-3.2%。
要点
- 2D-SWE肝硬度是预测高危静脉曲张的独立因素,可用于无创筛查。
- Baveno VI标准适用于2D-SWE测值,但节省内镜比例有限。
- 新标准LS<16 kPa且PLT>100×10⁹/L可更多免内镜且漏诊率<5%。
核心结论
- 2D-SWE测肝硬度可用于cACLD患者高危静脉曲张的无创筛查。
- 新标准LS<16 kPa且PLT>100×10⁹/L较Baveno VI标准节省更多内镜且漏诊率<5%。
研究设计与样本
- 单中心研究,纳入661例cACLD患者,均成功完成2D-SWE和内镜筛查。
- 以內镜为参考标准,分析高危静脉曲张的危险因素并比较不同预测标准的效能。
诊断标准与关键数值
- 排除高危静脉曲张的LS阈值为14.0 kPa,纳入高危静脉曲张的LS阈值为24.8 kPa。
- Baveno VI标准(LS<20 kPa且PLT>150×10⁹/L)漏诊率2.1%,节省内镜率19.2%。
- 新标准(LS<16 kPa且PLT>100×10⁹/L)在按肝病类型分层亚组中节省内镜30.4-34.6%,漏诊率0-3.2%。
临床应用与阅片要点
- 对cACLD患者可应用2D-SWE测肝硬度联合血小板计数筛选需内镜筛查者。
- 采用新标准可减少内镜负担,但需注意漏诊率仍存在,应结合临床综合判断。
局限性
- 单中心研究,结论需多中心验证。
- 亚组分析中不同肝病类型的结果可能存在异质性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the usefulness of the criteria with liver stiffness (LS) measured by two-dimensional shear wave elastography (2D-SWE) and platelet count (PLT) for ruling out high-risk varices in patients with compensated advanced chronic liver disease (cACLD).
METHODS: A total of 661 patients with cACLD had successfully undergone 2D-SWE and endoscopy screening. We analyzed risk factors for the presence of high-risk varices and compared proportions of patients who were spared endoscopy when used the predicting criteria with LS (ranged from 16 to 25 kPa) and PLT (ranged from 80 × 109/L to 150 × 109/L).
RESULTS: PLT, albumin, LS were found to be independent predictors of high-risk varices. The LS values for ruling out and ruling in high-risk varices were 14.0 kPa and 24.8 kPa, respectively. When the Baveno VI criteria LS < 20 kPa and PLT > 150 × 109/L were used, the high-risk varices miss rate was 2.1%, while the saved endoscopy rate only was 19.2%. The new criteria that LS < 16 kPa and PLT > 100 × 109/L saved 30.4-34.6% endoscopy with 0-3.2% high-risk varices miss rate in the subgroup analysis stratified according to the types of underlying liver disease.
CONCLUSIONS: The Baveno VI criteria can be applied to LS measurement by 2D-SWE. The new criteria that LS < 16 kPa and PLT > 100 × 109/L could be a potential model to spare more endoscopy screening with < 5% high-risk varices miss rate.
KEY POINTS: • LS measured by 2D-SWE is reliable predictive factor for predicting all-size varices and high-risk varices in patients with compensated advanced chronic liver disease. • LS measured by 2D-SWE < 16 kPa and PLT > 100 × 109 /L, which can spare more endoscopy than Baveno VI criteria with < 5% high-risk varices miss rate. • The Baveno VI criteria can be applied to LS measurement by 2D-SWE.
引用
- Yan Y, Xing X, Wang X, et al. Liver stiffness by two-dimensional shear wave elastography for screening high-risk varices in patients with compensated advanced chronic liver disease. Eur Radiol. 2021. PMID: 34713329. doi:10.1007/s00330-021-08280-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。