文献速递腹部CT

临床-CT模型与2D及3D影像组学模型预测进展期胃癌隐匿性腹膜转移的比较

Comparison of clinical-computed tomography model with 2D and 3D radiomics models to predict occult peritoneal metastases in advanced gastric cancer.
PubMed 文献 · Abdom Radiol (NY) · 2021-10-12

本研究回顾性纳入49例隐匿性腹膜转移和49例无腹膜转移的进展期胃癌患者,基于术前CT语义特征、临床信息及影像组学特征构建临床-CT模型与2D、3D影像组学模型,并在30例外部队列中验证。结果显示肿瘤大小、少量腹水及血清CA125为隐匿性腹膜转移的独立预测因素,临床-CT模型诊断效能优于2D和3D影像组学模型,其列线图具有较好的临床预测效率。

要点

  • 肿瘤大小、少量腹水、血清CA125是隐匿性腹膜转移的独立预测因素,阅片时应重点关注。
  • 外部验证中临床-CT模型AUC为0.853,优于2D影像组学模型的0.622和3D影像组学模型的0.676。
  • 临床-CT模型特异度达93.3%,但敏感度仅66.7%,阴性病例仍需结合其他信息综合判断。

核心结论

  • 临床-CT模型在预测进展期胃癌隐匿性腹膜转移方面优于2D和3D影像组学模型,其列线图具有较好的临床预测效率。

研究设计与样本

  • 回顾性研究,纳入49例隐匿性腹膜转移患者和49例无腹膜转移对照,均行术前CT并接受后续手术,时间范围为2016年1月至2018年12月。
  • 收集临床信息与CT语义特征并提取CT影像组学特征,采用多因素logistic回归构建临床-CT模型,采用最小绝对收缩和选择算子算法及logistic回归构建2D和3D影像组学模型。
  • 使用30例外部队列进行验证,以受试者工作特征曲线下面积、敏感度和特异度评价预测性能。

关键影像表现/征象

  • CT语义特征中肿瘤大小和少量腹水为隐匿性腹膜转移的独立预测因素,结合血清CA125构建临床-CT模型。
  • 原文未报告具体的影像征象定义、信号或密度阈值等细节。

诊断标准与关键数值

  • 外部验证队列中临床-CT模型AUC为0.853,敏感度66.7%,特异度93.3%。
  • 外部验证队列中2D影像组学模型AUC为0.622,敏感度80.0%,特异度46.7%。
  • 外部验证队列中3D影像组学模型AUC为0.676,敏感度60.0%,特异度86.0%。

临床应用与阅片要点

  • 术前CT阅片时应关注肿瘤大小、少量腹水等征象,并结合血清CA125综合评估隐匿性腹膜转移风险。
  • 临床-CT模型特异度高而敏感度有限,模型阴性者不能完全排除腹膜转移,需结合腹腔镜探查等进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the ability of a clinical-computed tomography (CT) model vs. 2D and 3D radiomics models for predicting occult peritoneal metastasis (PM) in patients with advanced gastric cancer (AGC).

METHODS: In this retrospective study, we included 49 patients with occult PM and 49 control patients (without PM) who underwent preoperative CT and subsequent surgery between January 2016 and December 2018. Clinical information and CT semantic features were collected, and CT radiomics features were extracted. A predictive clinical-CT model was created using multivariate logistic regression. The least absolute shrinkage and selection operator algorithm and logistic regression were used for constructing 2D and 3D radiomics models. These models were validated with an external cohort (n = 30). Receiver operating characteristics curve with area under the curve (AUC), sensitivity, and specificity were used to evaluate predictive performance.

RESULTS: Tumor size, mild ascites, and serum CA125 were independent factors predictive of occult PM. The clinical-CT model of these independent factors showed better diagnostic performance than 2D and 3D radiomics models. In the external validation cohort, the AUCs of different models were as follows-clinical-CT model: 0.853 (sensitivity, 66.7%; specificity, 93.3%); 2D radiomics model: 0.622 (sensitivity, 80.0%; specificity, 46.7%); and 3D radiomics model: 0.676 (sensitivity, 60.0%; specificity, 86.0%). The clinical-CT model nomogram showed good clinical predictive efficiency to assess occult PM.

CONCLUSION: The clinical-CT model was better than the radiomics models in predicting occult PM in AGC.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Huang J, Chen Y, Zhang Y, et al. Comparison of clinical-computed tomography model with 2D and 3D radiomics models to predict occult peritoneal metastases in advanced gastric cancer. Abdom Radiol (NY). 2021. PMID: 34636930. doi:10.1007/s00261-021-03287-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。