基于AI的心脏磁共振评估双心室功能:供应商间变异与测量误差的临床意义
结果显示LVEF和LVM与专家测量相关性良好,但RVEF相关性一般,且自动测量对左心室功能分级的准确性有限。
要点
- 深度学习自动测量的LVEF与专家测量相关性良好,但与结局的关联与专家相当。
- 自动LVEF在左心室功能分级(<35%、35%-50%、≥50%)上与专家分类的一致性有限。
- 深度学习RVEF与专家测量相关性一般,需进一步改进。
核心结论
- 自动深度学习与专家测量的LVEF一致性良好,且与结局的关联强度相似。
- 自动测量对左心室功能分级的准确性仍有限,可能影响治疗决策。
- 深度学习LVM与专家测量一致性良好,但深度学习RVEF需进一步优化。
研究设计与样本
- 使用3种全自动商业深度学习算法和一位临床专家(常规方法)测量LVEF、LVM和RVEF。
- 以临床专家测量作为参考标准,比较自动测量与专家测量的一致性及对主要不良心血管事件的预测能力。
诊断标准与关键数值
- LVEF分级标准:<35%、35%至50%、≥50%。
- 深度学习LVEF与专家LVEF相关性r=0.83-0.93;LVM相关性r=0.75-0.85;RVEF相关性r=0.59-0.68。
- 左心室LVEF误差>10%的病例占5%-18%,右心室占23%-43%。
- 3种深度学习LVEF分类与专家分类一致率分别为86%、80%、85%。
临床应用与阅片要点
- 自动LVEF和LVM测量可用于辅助评估,但功能分级需谨慎,建议结合专家复核。
- 深度学习RVEF测量误差较大,日常报告时应警惕其可靠性。
局限性
- 未报告供应商间变异的具体细节,仅使用3种商业算法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to determine whether left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) and left ventricular mass (LVM) measurements made using 3 fully automated deep learning (DL) algorithms are accurate and interchangeable and can be used to classify ventricular function and risk-stratify patients as accurately as an expert.
BACKGROUND: Artificial intelligence is increasingly used to assess cardiac function and LVM from cardiac magnetic resonance images.
METHODS: Two hundred patients were identified from a registry of individuals who underwent vasodilator stress cardiac magnetic resonance. LVEF, LVM, and RVEF were determined using 3 fully automated commercial DL algorithms and by a clinical expert (CLIN) using conventional methodology. Additionally, LVEF values were classified according to clinically important ranges: <35%, 35% to 50%, and ≥50%. Both ejection fraction values and classifications made by the DL ejection fraction approaches were compared against CLIN ejection fraction reference. Receiver-operating characteristic curve analysis was performed to evaluate the ability of CLIN and each of the DL classifications to predict major adverse cardiovascular events.
RESULTS: Excellent correlations were seen for each DL-LVEF compared with CLIN-LVEF (r = 0.83-0.93). Good correlations were present between DL-LVM and CLIN-LVM (r = 0.75-0.85). Modest correlations were observed between DL-RVEF and CLIN-RVEF (r = 0.59-0.68). A >10% error between CLIN and DL ejection fraction was present in 5% to 18% of cases for the left ventricle and 23% to 43% for the right ventricle. LVEF classification agreed with CLIN-LVEF classification in 86%, 80%, and 85% cases for the 3 DL-LVEF approaches. There were no differences among the 4 approaches in associations with major adverse cardiovascular events for LVEF, LVM, and RVEF.
CONCLUSIONS: This study revealed good agreement between automated and expert-derived LVEF and similarly strong associations with outcomes, compared with an expert. However, the ability of these automated measurements to accurately classify left ventricular function for treatment decision remains limited. DL-LVM showed good agreement with CLIN-LVM. DL-RVEF approaches need further refinements.
引用
- Wang S, Patel H, Miller T, et al. AI Based CMR Assessment of Biventricular Function: Clinical Significance of Intervendor Variability and Measurement Errors. JACC Cardiovasc Imaging. 2021. PMID: 34656471. doi:10.1016/j.jcmg.2021.08.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。