冠脉CT血流储备分数在经导管主动脉瓣置换术前的临床结局预测价值
本回顾性观察研究纳入196例接受TAVR评估的重度主动脉瓣狭窄患者,采用本地机器学习算法计算CT-FFR(异常阈值≤0.75)。中位随访18个月,MACE发生率为16%,全因死亡率为19%。CT-FFR与MACE独立相关(校正后HR=4.0),加入CT-FFR可改善CCTA及临床数据模型对MACE的预测价值(C-index=0.71),但与全因死亡率无关。
要点
- CT-FFR≤0.75与TAVR候选者MACE风险独立相关,校正后HR为4.0。
核心结论
- CT-FFR与TAVR候选者的主要不良心脏事件(MACE)独立相关,并改善CCTA评估的预测价值。
- CT-FFR对全因死亡率无显著预测作用。
研究设计与样本
- CT-FFR采用本地机器学习算法半自动获得,异常定义为≤0.75。
- 临床终点为MACE(非致死性心肌梗死、不稳定型心绞痛、心源性死亡或心力衰竭入院)和全因死亡率,中位随访18个月。
- 采用生存分析和C-index评估预测模型性能,似然比χ2检验比较嵌套模型。
诊断标准与关键数值
- CT-FFR异常阈值定义为≤0.75(基于本地机器学习算法)。
临床应用与阅片要点
- 在TAVR术前CCTA评估中,可计算CT-FFR(阈值≤0.75)以辅助识别MACE高风险患者。
- CT-FFR不应单独用于预测全因死亡率,其价值主要体现在MACE风险分层。
局限性
- 单中心回顾性研究设计。
- 样本量有限(196例),事件数较少(MACE 31例,全因死亡38例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background The role of CT angiography-derived fractional flow reserve (CT-FFR) in pre-transcatheter aortic valve replacement (TAVR) assessment is uncertain. Purpose To evaluate the predictive value of on-site machine learning-based CT-FFR for adverse clinical outcomes in candidates for TAVR. Materials and Methods This observational retrospective study included patients with severe aortic stenosis referred to TAVR after coronary CT angiography (CCTA) between September 2014 and December 2019. Clinical end points comprised major adverse cardiac events (MACE) (nonfatal myocardial infarction, unstable angina, cardiac death, or heart failure admission) and all-cause mortality. CT-FFR was obtained semiautomatically using an on-site machine learning algorithm. The ability of CT-FFR (abnormal if ≤0.75) to predict outcomes and improve the predictive value of the current noninvasive work-up was assessed. Survival analysis was performed, and the C-index was used to assess the performance of each predictive model. To compare nested models, the likelihood ratio χ2 test was performed. Results A total of 196 patients (mean age ± standard deviation, 75 years ± 11; 110 women [56%]) were included; the median time of follow-up was 18 months. MACE occurred in 16% (31 of 196 patients) and all-cause mortality in 19% (38 of 196 patients). Univariable analysis revealed CT-FFR was predictive of MACE (hazard ratio [HR], 4.1; 95% CI: 1.6, 10.8; P = .01) but not all-cause mortality (HR, 1.2; 95% CI: 0.6, 2.2; P = .63). CT-FFR was independently associated with MACE (HR, 4.0; 95% CI: 1.5, 10.5; P = .01) when adjusting for potential confounders. Adding CT-FFR as a predictor to models that include CCTA and clinical data improved their predictive value for MACE (P = .002) but not all-cause mortality (P = .67), and it showed good discriminative ability for MACE (C-index, 0.71). Conclusion CT angiography-derived fractional flow reserve was associated with major adverse cardiac events in candidates for transcatheter aortic valve replacement and improved the predictive value of coronary CT angiography assessment. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Choe in this issue.
引用
- Aquino GJ, Abadia AF, Schoepf UJ, et al. Coronary CT Fractional Flow Reserve before Transcatheter Aortic Valve Replacement: Clinical Outcomes. Radiology. 2021. PMID: 34609200. doi:10.1148/radiol.2021210160
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。