研究旨在建立一种微创的大动物老化血栓模型以评估溶栓技术。通过在静脉内放置支架将血栓锚定于血管壁,采用经皮微创方法在猪体内形成亚急性静脉血栓,所有受试者血栓至少保持完整1周。该模型可控制血栓年龄,为超声溶栓技术评价提供平台。

要点

  • 经皮微创置入静脉支架锚定血栓可稳定形成猪亚急性静脉血栓。
  • 血栓年龄可控,所有受试者血栓至少完整维持1周。
  • 该模型适用于评估针对老化血栓的超声溶栓技术。

局限性

  • 原文未明确报告样本量及统计效能。
  • 动物模型结果外推至临床需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

As blood clots age, many thrombolytic techniques become less effective. To fully evaluate these techniques for potential clinical use, a large animal aged-clot model is needed. Previous minimally invasive attempts to allow clots to age in an in vivo large animal model were unsuccessful because of the clot clearance associated with relatively high level of cardiac health of readily available research pigs. Prior models have thus subsequently used invasive surgical techniques with the associated morbidity, animal stress and cost. We propose a method for forming sub-acute venous blood clots in an in-vivo porcine model. The age of the clots can be controlled and varied. By using an intravenous scaffold to anchor the clot to the vessel wall during the aging process, we can show that sub-acute clots can consistently be formed with a minimally invasive, percutaneous approach. The clot formed in this study remained intact for at least 1 wk in all subjects. Therefore, we established a new minimally invasive, large animal aged-clot model for evaluation of thrombolytic techniques.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Stocker GE, Shi J, Ives K, et al. In Vivo Porcine Aged Deep Vein Thrombosis Model for Testing Ultrasound-based Thrombolysis Techniques. Ultrasound Med Biol. 2021. PMID: 34593277. doi:10.1016/j.ultrasmedbio.2021.08.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。