文献速递心血管外周血管CT

基于配准的半自动主动脉直径增长率评估优于手动量化

Registration-based semi-automatic assessment of aortic diameter growth rate from contrast-enhanced computed tomography outperforms manual quantification.
PubMed 文献 · Eur Radiol · 2021-10-16

配准法显示低偏倚、极佳一致性,且增长率可重复性显著高于手动法,6个月随访即可获得与手动法约3年随访相当的可重复性。

要点

  • 配准法测量主动脉直径与手动法一致性极佳(ICC=0.99),偏倚仅0.46 mm。
  • 配准法评估增长率可重复性远高于手动法(根部ICC 0.96 vs 0.68;胸主动脉0.96 vs 0.80)。
  • 配准法6个月随访的增长率可重复性与手动法2.7年随访相当。

核心结论

  • 基于配准的CTA主动脉扩张评估准确,且可重复性显著优于当前手动标准。
  • 该技术可在短至6个月的随访中稳健评估增长率,并提供超越预设解剖标志的3D直径与增长率映射。

研究设计与样本

  • 由两名独立观察者使用可变形图像配准在主动脉根部和整个胸主动脉获取直径与增长率,并与典型解剖标志处的手动标准比较。

诊断标准与关键数值

  • 配准法与手动法相比,主动脉直径偏倚0.46 mm,一致性ICC=0.99,观察者间可重复性ICC均为0.99。
  • 增长率偏倚0.10 mm/年,一致性ICC=0.82;观察者间可重复性根部ICC=0.96 vs 0.68,胸主动脉ICC=0.96 vs 0.80。
  • 配准法6个月随访增长率可重复性LoA为[-0.01, 0.33] mm/年,手动法2.7年随访为[-0.13, 0.21] mm/年。
  • 全胸主动脉直径与增长率映射高度可重复(ICC>0.9)。

临床应用与阅片要点

  • 配准法可用于短至6个月随访的主动脉扩张监测,提高增长率评估的可重复性。
  • 3D映射有助于超越预设解剖标志评估主动脉直径和增长率。

局限性

  • 研究未报告手动评估增长率可重复性的具体数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Manual assessment of aortic diameters on double-oblique reformatted computed tomography angiograms (CTA) is considered the current standard, although the reproducibility for growth rates has not been reported. Deformable registration of CTA has been proposed to provide 3D aortic diameters and growth maps, but validation is lacking. This study aimed to quantify accuracy and inter-observer reproducibility of registration-based and manual assessment of aortic diameters and growth rates.

METHODS: Forty patients with ≥ 2 CTA acquired at least 6 months apart were included. Aortic diameters and growth rate were obtained in the aortic root and the entire thoracic aorta using deformable image registration by two independent observers, and compared with the current standard at typical anatomical landmarks.

RESULTS: Compared with manual assessment, the registration-based technique presented low bias (0.46 mm), excellent agreement (ICC = 0.99), and similar inter-observer reproducibility (ICC = 0.99 for both) for aortic diameters; and low bias (0.10 mm/year), good agreement (ICC = 0.82), and much higher inter-observer reproducibility for growth rates (root: ICC = 0.96 vs 0.68; thoracic aorta: ICC = 0.96 vs 0.80). Registration-based growth rate reproducibility over a 6-month-long follow-up was similar to that obtained by manual assessment after 2.7 years (LoA = [- 0.01, 0.33] vs [- 0.13, 0.21] mm/year, respectively). Mapping of diameter and growth rate was highly reproducible (ICC > 0.9) in the whole thoracic aorta.

CONCLUSIONS: Registration-based assessment of aortic dilation on CTA is accurate and substantially more reproducible than the current standard, even at follow-up as short as 6 months, and provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks.

KEY POINTS: • Registration-based semi-automatic assessment of progressive aortic dilation on CTA is accurate and substantially more reproducible than the current standard. • The registration-based technique allows robust growth rate assessment at follow-up as short as 6 months, with a similar reproducibility to that obtained by manual assessment at around 3 years. • The use of image registration provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Dux-Santoy L, Rodríguez-Palomares JF, Teixidó-Turà G, et al. Registration-based semi-automatic assessment of aortic diameter growth rate from contrast-enhanced computed tomography outperforms manual quantification. Eur Radiol. 2021. PMID: 34655311. doi:10.1007/s00330-021-08273-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。