文献速递胸部US

基于香农熵的肺超声灰度图像定量评估肺通气:一项动物研究

Quantitative Assessment of Lung Ultrasound Grayscale Images Based on Shannon Entropy for the Detection of Pulmonary Aeration: An Animal Study.
PubMed 文献 · J Ultrasound Med · 2021-10-26

本研究在32只新西兰兔中通过静脉注射油酸诱导不同 degree 的肺水肿,使用临床床旁超声系统获取灰度肺超声图像,通过灰度直方图分析估计香农熵(ShanEn),并与 gravimetry 测定的湿干重比(W/D)进行相关性分析。结果显示 ShanEn 与 W/D 的线性相关决定系数随增益和动态范围(DR)增加而提高(从0.0487升至0.7477),提示 ShanEn 有潜力为肺通气提供客观信息,但需要高增益和高 DR 采集图像。

要点

  • ShanEn 与肺湿干重比的相关性随增益和动态范围增加而提高,最高决定系数为0.7477。
  • 定量分析肺通气需采用高增益和高动态范围设置,与视觉评分方法常用设置不同。
  • 基于灰度直方图的 ShanEn 无需原始数据,可在常规超声系统上实现客观肺通气评估。

诊断标准与关键数值

  • ShanEn 与 W/D 的线性相关决定系数在增益和动态范围变化下从0.0487升至0.7477。
  • 定量肺通气需高增益和高动态范围,而视觉评分方法使用中等增益和低动态范围。

临床应用与阅片要点

  • 日常肺超声定量评估肺通气时,应考虑采用高增益和高动态范围设置采集图像以优化 ShanEn 与肺水含量的相关性。
  • ShanEn 基于灰度直方图分析,无需原始射频数据,可在常规超声系统上实现,便于临床转化。

局限性

  • 本研究为动物实验,样本量32只兔,结果外推到人类临床需进一步验证。
  • 研究仅使用油酸性肺水肿模型,未涵盖其他类型肺通气改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Lung ultrasound (LUS) is a radiation-free, affordable, and bedside monitoring method that can detect changes in pulmonary aeration before hypoxic damage. However, visual scoring methods of LUS only enable subjective diagnosis. Therefore, quantitative analysis of LUS is necessary for obtaining objective information on pulmonary aeration. Because raw data are not always available in conventional ultrasound systems, Shannon entropy (ShanEn) of information theory without the requirement of raw data is valuable. In this study, we explored the feasibility of ShanEn estimated through grayscale histogram (GSH) analysis of LUS images for the quantification of pulmonary aeration.

METHODS: Different degrees of pulmonary aeration caused by edema was induced in 32 male New Zealand rabbits intravenously injected with 0.1 mL/kg saline (the control group) and 0.025, 0.05, and 0.1 mL/kg oleic acid (mild, moderate, and severe groups, respectively). In vivo grayscale LUS images were acquired using a commercial point-of-care ultrasound system for estimation of GSH and corresponding ShanEn. Both lungs of each rabbit were dissected, weighed, and dried to determine the wet weight-to-dry weight ratio (W/D) through gravimetry.

RESULTS: The determination coefficients of linear correlations between ShanEn and W/D increased from 0.0487 to 0.7477 with gain and dynamic range (DR). In contrast to visual scoring methods of pulmonary aeration that use median gain and low DR, ShanEn for quantifying pulmonary aeration requires high gain and DR.

CONCLUSION: The current findings indicate that ShanEn estimated through GSH analysis of LUS images acquired using conventional ultrasonic imaging systems has great potential to provide objective information on pulmonary aeration.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Fang J, Ting YN, Chen YW, et al. Quantitative Assessment of Lung Ultrasound Grayscale Images Based on Shannon Entropy for the Detection of Pulmonary Aeration: An Animal Study. J Ultrasound Med. 2021. PMID: 34698398. doi:10.1002/jum.15851

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。