PubMed 文献 · Radiology · 2021-10-26

回顾性纳入5例有MRI禁忌证的女性胸部淋巴管疾病患者,经超声引导双侧腹股沟淋巴结注射水溶性碘对比剂行CT淋巴管造影,4例中枢淋巴管显影并显示异常肺淋巴回流,与后续胸导管淋巴管造影结果吻合良好。

要点

  • 超声引导下25G针穿刺双侧腹股沟淋巴结注射水溶性碘对比剂可行。
  • CT透视监测乳糜池显影决定CT扫描时机,胸导管显影时间2–27分钟。
  • ICTL与胸导管淋巴管造影三维重建所见吻合良好。

关键影像表现/征象

  • 5例中4例中枢淋巴管显影,显示胸导管至肺实质的异常肺淋巴回流。
  • 1例经胸导管注射显示胸导管结扎成功。
  • 注射对比剂至胸导管显影时间为2–27分钟。

临床应用与阅片要点

  • 对MRI禁忌的胸部淋巴管疾病患者,可考虑经淋巴结CT淋巴管造影评估中枢淋巴解剖。
  • 用CT透视监测乳糜池显影以确定CT扫描时机,避免过早或过晚成像。

局限性

  • 回顾性研究,样本量仅5例。
  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Dynamic contrast-enhanced MR lymphangiography (DCMRL) is the reference standard used to diagnose various thoracic lymphatic disorders, such as traumatic chylothorax and plastic bronchitis. However, accessibility and logistical challenges have prevented the wide dissemination of this technology. Purpose To evaluate the feasibility of intranodal CT lymphangiography (ICTL) in the diagnosis and planning of subsequent intervention in patients with thoracic lymphatic disorders. Materials and Methods In this retrospective review, five women suspected of having lymphatic abnormalities (ranging from traumatic chylothorax to plastic bronchitis) and with contraindications to MRI underwent ICTL from September 2019 to May 2020. Needles (25 gauge) were placed in the bilateral inguinal lymph nodes with US guidance, and water-soluble iodinated contrast material was injected. CT fluoroscopy was used to monitor the opacification of the cisterna chyli to determine the timing of CT. After ICTL, the thoracic duct was catheterized, and lymphangiography was performed through the thoracic duct catheter. The ICTL and subsequent lymphangiographic findings were then visually compared by using three-dimensional reconstructions. Results Intranodal injection of water-soluble contrast medium was successful in all patients evaluated (five women; mean age, 68 years ± 11 [standard deviation]; range, 53-83 years). The central lymphatics were opacified in four of the five women, demonstrating abnormal pulmonary lymphatic flow from the thoracic duct into the lung parenchyma. In one of the five women, thoracic duct injection showed successful ligation of the thoracic duct. The time elapsed from injection of contrast medium to visualization of the thoracic duct ranged from 2 to 27 minutes. ICTL and lymphangiographic findings matched well. Conclusion Intranodal CT lymphangiography sufficiently depicted central lymphatic anatomy in patients with lymphatic abnormalities, thereby demonstrating its use as a feasible alternative to more technically challenging methods, such as dynamic contrast-enhanced MR lymphangiography. © RSNA, 2021.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Patel S, Hur S, Khaddash T, et al. Intranodal CT Lymphangiography with Water-soluble Iodinated Contrast Medium for Imaging of the Central Lymphatic System. Radiology. 2021. PMID: 34698570. doi:10.1148/radiol.2021210294

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。