头颈部MRI:GRASP-VIBE与脂肪抑制T1WI TSE增强序列的个体内比较
这项回顾性研究纳入52例头颈部MRI患者,个体内比较了钆增强后GRASP-VIBE与脂肪抑制T1WI TSE序列的图像质量。结果显示GRASP-VIBE在整体图像质量、伪影、口咽/下咽黏膜及颈部淋巴结显示方面评分均显著更高(均P<.001),SNR也显著更高(P<.001),但对比噪声比差异无统计学意义(P=.059)。
要点
- GRASP-VIBE增强序列在头颈部图像质量与伪影控制上优于传统脂肪抑制T1WI TSE。
- GRASP-VIBE对下咽黏膜和颈部淋巴结的显示更清晰,有利于病灶检出。
- GRASP-VIBE的SNR显著更高,但对比噪声比未达统计学显著差异。
关键影像表现/征象
- GRASP-VIBE在整体图像质量评分上显著高于脂肪抑制T1WI TSE(4.68±0.41 vs 3.66±0.73,P<.001)。
- GRASP-VIBE在整体伪影评分上显著更高(4.47±0.48 vs 3.58±0.71,P<.001),提示伪影更少。
- GRASP-VIBE在口咽黏膜清晰度(4.85±0.41 vs 4.11±0.79)、下咽黏膜清晰度(4.84±0.34 vs 3.58±0.81)及颈部淋巴结清晰度(4.79±0.32 vs 4.08±0.64)上均显著更高(均P<.001)。
诊断标准与关键数值
- 图像质量、伪影及结构清晰度采用5分法评分,最佳为5分。
- 观察者间一致性加权κ值范围0.18(颈部淋巴结清晰度,轻微一致)至0.80(口咽黏膜清晰度,高度一致)。
- GRASP-VIBE的SNR显著高于脂肪抑制T1WI TSE(22.8±11.5 vs 11.3±5.6,P<.001)。
- GRASP-VIBE的对比噪声比与脂肪抑制T1WI TSE相比差异无统计学意义(4.7±5.4 vs 2.3±2.7,P=.059)。
临床应用与阅片要点
- 在头颈部增强MRI中可优先选用GRASP-VIBE序列,以改善图像质量和减少伪影。
- GRASP-VIBE对下咽黏膜和颈部淋巴结的清晰显示有助于评估肿瘤范围及淋巴结转移。
- 注意观察者间对颈部淋巴结清晰度评分一致性仅轻微(κ=0.18),报告时需结合多序列综合判断。
局限性
- 回顾性研究,可能存在选择偏倚。
- 单中心研究,样本量有限(最终分析52例)。
- 未报告对诊断准确性的影响,仅评估图像质量主观评分和客观SNR/CNR。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The golden-angle radial sparse parallel-volumetric interpolated breath-hold (GRASP-VIBE) sequence is a recently introduced imaging technique with high resolution. This study compared the image quality between conventional fat-suppressed T1-weighted TSE and GRASP-VIBE after gadolinium enhancement in the head and neck region.
MATERIALS AND METHODS: Data from 65 patients with clinical indications for head and neck MR imaging between September 2020 and January 2021 were retrospectively reviewed. Two radiologists assessed the overall image quality, overall artifacts, and image conspicuities in the oropharynx, hypopharynx, and cervical lymph nodes according to 5-point scores (best score: 5). Interobserver agreement was assessed using weighted κ statistics. The SNR and contrast-to-noise ratio were calculated and compared between the 2 sequences using a paired Wilcoxon signed rank test.
RESULTS: The analysis included 52 patients (mean age, 60 [SD, 14 ] years; male, 71.2% [37/52]) who were mostly diagnosed with head and neck malignancies (94.3% [50/52]). κ statistics ranged from slight agreement in cervical lymph node conspicuity (κ = 0.18) to substantial agreement in oropharyngeal mucosal conspicuity (κ = 0.80) (κ range, 0.18-0.80). Moreover, GRASP-VIBE demonstrated significantly higher mean scores in overall image quality (4.68 [SD, 0.41] versus 3.66 [SD, 0.73]), artifacts (4.47 [SD, 0.48] versus 3.58 [SD, 0.71]), oropharyngeal mucosal conspicuity (4.85 [SD, 0.41] versus 4.11 [SD, 0.79]), hypopharyngeal mucosal conspicuity (4.84 [SD, 0.34] versus 3.58 [SD, 0.81]), and cervical lymph node conspicuity (4.79 [SD, 0.32] versus 4.08 [SD, 0.64]) than fat-suppressed T1-weighted TSE (all, P < .001). Furthermore, GRASP-VIBE demonstrated a higher SNR (22.8 [SD, 11.5] versus 11.3 [SD, 5.6], P < .001) and contrast-to-noise ratio (4.7 [SD, 5.4] versus 2.3 [SD, 2.7], P = .059) than fat-suppressed T1-weighted TSE.
CONCLUSIONS: GRASP-VIBE provided better image quality with fewer artifacts than conventional fat-suppressed T1-weighted TSE for the head and neck regions.
引用
- Hur SJ, Choi Y, Yoon J, et al. Intraindividual Comparison between the Contrast-Enhanced Golden-Angle Radial Sparse Parallel Sequence and the Conventional Fat-Suppressed Contrast-Enhanced T1-Weighted Spin-Echo Sequence for Head and Neck MRI. AJNR Am J Neuroradiol. 2021. PMID: 34593379. doi:10.3174/ajnr.A7285
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。