文献速递儿科影像技术与安全CT

美国10项儿科CT检查的诊断参考水平与可达到剂量

U.S. Diagnostic Reference Levels and Achievable Doses for 10 Pediatric CT Examinations.
PubMed 文献 · Radiology · 2021-10-26

基于美国放射学会剂量指数登记处2016至2020年1625家机构、1543535次儿科CT检查数据,按年龄和有效直径建立了10项最常见儿科CT检查的国家诊断参考水平与可达到剂量。头颈部按年龄分析,体部按年龄和有效直径分析,头CT占比最高(876655/1543535,57%)。

要点

  • 建立了按年龄和有效直径分层的10项儿科CT检查诊断参考水平与可达到剂量,可用于调整儿科CT协议和剂量。
  • 头部平扫CT的CTDIvol可达到剂量随年龄从19增至46 mGy,诊断参考水平从23增至55 mGy,均随年龄增加。
  • 体部检查的CTDIvol、SSDE和DLP的诊断参考水平与可达到剂量均随患者有效直径增加而一致升高。

核心结论

  • 利用美国放射学会剂量指数登记处数据,按患者年龄和有效直径建立了10项最常见儿科CT检查的诊断参考水平与可达到剂量,这些基准可指导CT机构调整儿科CT协议及相应剂量。

研究设计与样本

  • 基于美国放射学会剂量指数登记处的分析,纳入2016至2020年1625家机构、1543535次18岁及以下患者儿科CT检查;头颈部检查按患者年龄分析剂量指数,体部检查按患者年龄和有效直径分析。

诊断标准与关键数值

  • 可达到剂量取中位数,诊断参考水平取第75百分位数,指标包括容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)和体型特异性剂量估算(SSDE);头部平扫CT的CTDIvol可达到剂量为19至46 mGy、诊断参考水平为23至55 mGy,均随年龄增加。

临床应用与阅片要点

  • 作者指出这些基准可指导CT机构调整儿科CT协议及相应剂量,但原文未据此给出具体推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry. Purpose To develop robust, current, national DRLs and ADs for the 10 most commonly performed pediatric CT examinations as a function of patient age and size. Materials and Methods Data on 10 pediatric (ie, patients aged 18 years and younger) CT examinations performed between 2016 and 2020 at 1625 facilities were analyzed. For head and neck examinations, dose indexes were analyzed based on patient age; for body examinations, dose indexes were analyzed for patient age and effective diameter. Data from 1 543 535 examinations provided medians for AD and 75th percentiles for DRLs for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE). Results Of all facilities analyzed, 66% of the facilities (1068 of 1625) were community hospitals, 16% (264 of 1625) were freestanding centers, 9.5% (154 of 1625) were academic facilities, and 3.5% (57 of 1625) were dedicated children's hospitals. Fifty-two percent of the patients (798 577 of 1 543 535) were boys, and 48% (744 958 of 1 543 535) were girls. The median age of patients was 14 years (boys, 13 years; girls, 15 years). The head was the most frequent anatomy examined with CT (876 655 of 1 543 535 examinations [57%]). For head without contrast material CT examinations, the age-based CTDIvol AD ranged from 19 to 46 mGy, and DRL ranged from 23 to 55 mGy, with both AD and DRL increasing with age. For body examinations, DRLs and ADs for size-based CTDIvol, SSDE, and DLP increased consistently with the patient's effective diameter. Conclusion Diagnostic reference levels and achievable doses as a function of patient age and effective diameter were developed for the 10 most commonly performed CT pediatric examinations using American College of Radiology Dose Index Registry data. These benchmarks can guide CT facilities in adjusting pediatric CT protocols and resultant doses for their patients. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on October 29, 2021.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kanal KM, Butler PF, Chatfield MB, et al. U.S. Diagnostic Reference Levels and Achievable Doses for 10 Pediatric CT Examinations. Radiology. 2021. PMID: 34698569. doi:10.1148/radiol.2021211241

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。