文献速递神经介入DSA

血管内治疗后血管再通后动脉直径比值预测急性缺血性卒中临床结局

Artery diameter ratio after recanalization in endovascular therapy for acute ischemic stroke: a new predictor of clinical outcomes.
PubMed 文献 · Neuroradiology · 2021-10-27

本研究回顾性分析143例大脑中动脉闭塞经血管内治疗且获TICI 2b/3再通的患者,计算再通后M2/M1段直径比值(ADR)。ADR<0.6组出院NIHSS更高、90天功能独立比例更低(20.97% vs 83.95%,OR 0.05),脑水肿和sICH发生率更高;ADR对mRS>2的AUC为0.851,最佳阈值0.6(敏感度75.81%,特异度85.19%)。

要点

  • 再通后ADR<0.6提示不良结局,阅片时应关注M2/M1直径比。
  • ADR对mRS>2的AUC为0.851,阈值0.6时敏感度75.81%、特异度85.19%。
  • ADR降低可能与脑血管自动调节功能丧失有关。

关键影像表现/征象

  • ADR计算为M2段直径/M1段直径,再通后ADR<0.6组出院NIHSS显著高于ADR≥0.6组(均值16.37 vs 6.19,P<0.001)。
  • ADR<0.6组90天功能独立比例显著低于另一组(20.97% vs 83.95%,OR 0.05,95%CI 0.02-0.12,P<0.001)。
  • ADR<0.6组脑水肿发生率更高(P=0.027),症状性颅内出血发生率更高(P=0.038)。

诊断标准与关键数值

  • ADR对mRS>2的鉴别能力最强,AUC=0.851,最佳截断值0.6,特异度85.19%,敏感度75.81%。
  • ADR对DC的AUC=0.805,最佳截断值0.58,特异度65.96%,敏感度100%。

临床应用与阅片要点

  • 血管再通后应测量M1、M2段直径并计算ADR,ADR<0.6提示预后不良风险增高。
  • ADR降低可能反映脑血管自动调节受损,可作为术后评估的辅助指标。

局限性

  • 回顾性研究,样本量143例,单中心设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aimed to investigate the relationship between the artery diameter ratio (ADR) after recanalization and clinical outcomes.

METHODS: Patients with middle cerebral artery occlusion confirmed by DSA from 1 January 2018, to 31 December 2019, were retrospectively analyzed. All patients confirmed TICI grade 2b or 3. The ADR was calculated as M2 segment diameter/M1 segment diameter. Multivariate regression analysis was used to describe clinical outcomes of two groups (ADR < 0.6 and ≥ 0.6). ROC curves were used to compare different models and find the best cutoff.

RESULTS: A total of 143 patients were included in the study, including 77 males and 66 females, with an average age of 67.79 ± 12 years. The NIHSS at discharge was significantly higher in the ADR < 0.6 group than another group (mean, 16.37 vs. 6.19, P < 0.001). At 90 days, the cases of functional independence was significantly less in the ADR < 0.6 group (20.97% vs. 83.95%, OR 0.05, 95% CI 0.02-0.12, P < 0.001). The ADR < 0.6 group had a higher incidence of cerebral edema (P = 0.027) and sICH (P = 0.038). The ADR had the strongest power to distinguish mRS > 2 (AUC = 0.851) and DC (AUC = 0.805), and the best cutoff value are 0.6 (specificity 85.19%, sensitivity 75.81%) and 0.58 (specificity 65.96%, sensitivity 100%), respectively.

CONCLUSION: The low ADR is associated with poor outcomes. The decrease in ADR may be an indirect manifestation of the loss of cerebrovascular autoregulation.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Huang S, Liu C, Li X, et al. Artery diameter ratio after recanalization in endovascular therapy for acute ischemic stroke: a new predictor of clinical outcomes. Neuroradiology. 2021. PMID: 34708259. doi:10.1007/s00234-021-02841-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。