文献速递神经MR

人工智能合成缺失序列改善胶质瘤自动分割的临床常规应用

Improving Automated Glioma Segmentation in Routine Clinical Use Through Artificial Intelligence-Based Replacement of Missing Sequences With Synthetic Magnetic Resonance Imaging Scans.
PubMed 文献 · Invest Radiol · 2022-01-01

本研究开发并验证了一种生成对抗网络,用于从可用序列合成缺失的FLAIR、T2加权、T1加权或增强T1加权图像,以支持稳健的自动分割。模型在癌症影像档案库(n=238)训练,在REMBRANDT和本机构测试集(n=68)验证,合成图像在多数情况下优于常规缺失数据处理方法,尤其当FLAIR缺失时,水肿和全肿瘤分割的Dice分数分别提升12%和11%,但无法可靠替代缺失的增强T1加权图像。

要点

  • 合成缺失的非增强MR序列可显著提高胶质瘤自动分割质量,尤其FLAIR缺失时。
  • 增强T1w缺失时,合成方法不可靠,需谨慎解读分割结果。
  • 该模型免费可用,有助于在常规临床中推广自动分割。

局限性

  • 无法可靠替代缺失的增强T1w图像。
  • 研究为回顾性设计,训练和测试数据来自特定数据库和单中心,外部泛化性需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Although automated glioma segmentation holds promise for objective assessment of tumor biology and response, its routine clinical use is impaired by missing sequences, for example, due to motion artifacts. The aim of our study was to develop and validate a generative adversarial network for synthesizing missing sequences to allow for a robust automated segmentation.

MATERIALS AND METHODS: Our model was trained on data from The Cancer Imaging Archive (n = 238 WHO II-IV gliomas) to synthesize either missing FLAIR, T2-weighted, T1-weighted (T1w), or contrast-enhanced T1w images from available sequences, using a novel tumor-targeting loss to improve synthesis of tumor areas. We validated performance in a test set from both the REMBRANDT repository and our local institution (n = 68 WHO II-IV gliomas), using qualitative image appearance metrics, but also segmentation performance with state-of-the-art segmentation models. Segmentation of synthetic images was compared with 2 commonly used strategies for handling missing input data, entering a blank mask or copying an existing sequence.

RESULTS: Across tumor areas and missing sequences, synthetic images generally outperformed both conventional approaches, in particular when FLAIR was missing. Here, for edema and whole tumor segmentation, we improved the Dice score, a common metric for evaluation of segmentation performance, by 12% and 11%, respectively, over the best conventional method. No method was able to reliably replace missing contrast-enhanced T1w images.

DISCUSSION: Replacing missing nonenhanced magnetic resonance sequences via synthetic images significantly improves segmentation quality over most conventional approaches. This model is freely available and facilitates more widespread use of automated segmentation in routine clinical use, where missing sequences are common.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Thomas MF, Kofler F, Grundl L, et al. Improving Automated Glioma Segmentation in Routine Clinical Use Through Artificial Intelligence-Based Replacement of Missing Sequences With Synthetic Magnetic Resonance Imaging Scans. Invest Radiol. 2022. PMID: 34652289. doi:10.1097/RLI.0000000000000828

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。