文献速递神经外周血管MR

7 T与3 T血管壁MRI评估颅内动脉瘤壁的比较

Comparison of 7 T and 3 T vessel wall MRI for the evaluation of intracranial aneurysm wall.
PubMed 文献 · Eur Radiol · 2021-10-13

前瞻性纳入24例颅内未破裂动脉瘤患者,同时行3 T和7 T三维T1加权血管壁成像,比较动脉瘤壁可见性、厚度量化及锐利度。7 T壁可见性评分和锐利度显著优于3 T,3 T测得的表观壁厚较7 T厚15%,且7 T壁厚与动脉瘤大小正相关。

要点

  • 7 T血管壁成像对颅内动脉瘤壁的显示和锐利度优于3 T。
  • 3 T测量的动脉瘤壁厚度较7 T高估约15%,报告时需注意场强差异。
  • 7 T测得的动脉瘤壁厚度与动脉瘤大小呈正相关。

关键影像表现/征象

  • 7 T动脉瘤壁可见性Likert评分显著高于3 T(3.6 ± 1.1 vs 2.7 ± 0.8,p = 0.003)。
  • 7 T壁锐利度较3 T高57%(1.95 ± 0.32 mm-1 vs 1.24 ± 0.15 mm-1,p < 0.001)。
  • 3 T与7 T的壁-腔对比率相当(p = 0.424)。

诊断标准与关键数值

  • 壁可见性采用0-5分Likert量表评估。
  • 表观壁厚采用半自动半高全宽(FWHM)方法量化。
  • 3 T与7 T测得的表观壁厚相关性良好(平均r = 0.63 ± 0.19),但3 T测值较7 T厚15%(0.52 ± 0.07 mm vs 0.45 ± 0.05 mm,p < 0.001)。
  • 7 T表观壁厚与动脉瘤大小正相关(囊状:r = 0.58,q = 0.046;梭形:r = 0.67,q = 0.049)。

临床应用与阅片要点

  • 阅读3 T血管壁成像时需注意其可能高估动脉瘤壁厚度,尤其在小动脉瘤中。
  • 7 T可用于更精细评估动脉瘤壁厚度及锐利度,但需结合场强特点判读。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the visibility of intracranial aneurysm wall and thickness quantification between 7 and 3 T vessel wall imaging and evaluate the association between aneurysm size and wall thickness.

METHODS: Twenty-nine patients with 29 unruptured intracranial aneurysms were prospectively recruited for 3D T1-weighted vessel wall MRI at both 3 T and 7 T with 0.53 mm (3 T) and 0.4 mm (7 T) isotropic resolution, respectively. Two neuroradiologists independently evaluated wall visibility (0-5 Likert scale), quantified the apparent wall thickness (AWT) using a semi-automated full-width-half-maximum method, calculated wall sharpness, and measured the wall-to-lumen contrast ratio (CRwall/lumen).

RESULTS: Twenty-four patients with 24 aneurysms were included in this study. 7 T achieved significantly better aneurysm wall visibility than 3 T (3.6 ± 1.1 vs 2.7 ± 0.8, p = 0.003). AWT measured on 3 T and 7 T had a good correlation (averaged r = 0.63 ± 0.19). However, AWT on 3 T was 15% thicker than that on 7 T (0.52 ± 0.07 mm vs 0.45 ± 0.05 mm, p < 0.001). Wall sharpness on 7 T was 57% higher than that on 3 T (1.95 ± 0.32 mm-1 vs 1.24 ± 0.15 mm-1, p < 0.001). CRwall/lumen on 3 T and 7 T was comparable (p = 0.424). AWT on 7 T was positively correlated with aneurysm size (saccular: r = 0.58, q = 0.046; fusiform: r = 0.67, q = 0.049).

CONCLUSIONS: 7 T provides better visualization of intracranial aneurysm wall with higher sharpness than 3 T. 3 T overestimates the wall thickness relative to 7 T. Aneurysm wall thickness is positively correlated with aneurysm size. 7 T MRI is a promising tool to evaluate aneurysm wall in vivo.

KEY POINTS: • 7 T provides better visualization of intracranial aneurysm wall with higher sharpness than 3 T. • 3 T overestimates the wall thickness comparing with 7 T. • Aneurysm wall thickness is positively correlated with aneurysm size.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Feng J, Liu X, Zhang Z, et al. Comparison of 7 T and 3 T vessel wall MRI for the evaluation of intracranial aneurysm wall. Eur Radiol. 2021. PMID: 34643780. doi:10.1007/s00330-021-08331-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。