人类颈髓滤波扩散加权MRI:可行性与在创伤性脊髓损伤中的应用
研究在3名健康受试者中评估滤波DWI序列,并对8例急性颈髓损伤患者于伤后24小时内行1.5T滤波DWI与DTI检查。滤波DWI的高强度扩散加权抑制了脊髓外肌肉和脑脊液信号,损伤层面平行ADC较最头侧区域下降38.71%,大于DTI轴向扩散率的17.68%降幅。结果表明滤波DWI在急性脊髓损伤场景可行,能显示常规DTI未显现的脊髓扩散特征。
要点
- 滤波DWI可抑制脊髓外肌肉和CSF信号,突出脊髓本身扩散特征。
- 急性脊髓损伤层面平行ADC下降幅度(38.71%)大于DTI轴向扩散率(17.68%)。
- 滤波DWI在伤后24小时内急性期可行,补充常规DTI信息。
核心结论
- 滤波DWI在急性脊髓损伤的急性期设置中可行,能揭示常规DTI未显现的脊髓扩散特征。
研究设计与样本
- 研究先在3名健康受试者中于3T评估MR成像协议,随后8例急性颈髓损伤患者在伤后24小时内在1.5T行滤波DWI与临床MR检查。
- DTI采用25个方向、b值800 s/mm²;滤波DWI采用脊髓优化的26方向扩散加权,滤波b值2000 s/mm²,探针最大b值1000 s/mm²。
关键影像表现/征象
- 垂直于脊髓的高强度扩散加权抑制了脊髓外组织信号,包括肌肉和脑脊液。
诊断标准与关键数值
- 损伤层面滤波DWI的平行ADC相对最头侧区域下降38.71%,DTI轴向扩散率下降17.68%。
临床应用与阅片要点
- 滤波DWI可作为急性脊髓损伤MRI协议的补充序列,用于观察脊髓扩散特征。
- 解读时注意滤波DWI的高b值设计对脊髓外信号的抑制作用,避免将抑制信号误判为病变。
局限性
- 健康受试者样本量仅3例,急性脊髓损伤患者仅8例,均为小样本。
- 滤波DWI在1.5T采集,健康受试者协议在3T评估,场强不一致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: In traumatic spinal cord injury, DTI is sensitive to injury but is unable to differentiate multiple pathologies. Axonal damage is a central feature of the underlying cord injury, but prominent edema confounds its detection. The purpose of this study was to examine a filtered DWI technique in patients with acute spinal cord injury.
MATERIALS AND METHODS: The MR imaging protocol was first evaluated in a cohort of healthy subjects at 3T (n = 3). Subsequently, patients with acute cervical spinal cord injury (n = 8) underwent filtered DWI concurrent with their acute clinical MR imaging examination <24 hours postinjury at 1.5T. DTI was obtained with 25 directions at a b-value of 800 s/mm2. Filtered DWI used spinal cord-optimized diffusion-weighting along 26 directions with a "filter" b-value of 2000 s/mm2 and a "probe" maximum b-value of 1000 s/mm2. Parallel diffusivity metrics obtained from DTI and filtered DWI were compared.
RESULTS: The high-strength diffusion-weighting perpendicular to the cord suppressed signals from tissues outside of the spinal cord, including muscle and CSF. The parallel ADC acquired from filtered DWI at the level of injury relative to the most cranial region showed a greater decrease (38.71%) compared with the decrease in axial diffusivity acquired by DTI (17.68%).
CONCLUSIONS: The results demonstrated that filtered DWI is feasible in the acute setting of spinal cord injury and reveals spinal cord diffusion characteristics not evident with conventional DTI.
引用
- Murphy SA, Furger R, Kurpad SN, et al. Filtered Diffusion-Weighted MRI of the Human Cervical Spinal Cord: Feasibility and Application to Traumatic Spinal Cord Injury. AJNR Am J Neuroradiol. 2021. PMID: 34620590. doi:10.3174/ajnr.A7295
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。