文献速递心血管外周血管PETMR

纤维蛋白靶向PET/MR检测左心耳血栓

Detection and Characterization of Thrombosis in Humans Using Fibrin-Targeted Positron Emission Tomography and Magnetic Resonance.
PubMed 文献 · JACC Cardiovasc Imaging · 2021-10-13

本研究在健康志愿者中评估[64Cu]FBP8的药代动力学,并对房颤患者行PET/CMR,以TEE为参考标准。结果显示LAA的SUVMax在TEE阳性组显著高于阴性组,AUC为0.97,SUVMax阈值2.6时敏感度100%、特异度84%;联合SUVMax与T1Min可100%准确分类。

要点

  • SUVMax阈值2.6诊断左心耳血栓敏感度100%,特异度84%。
  • 联合SUVMax与T1Min可100%准确区分TEE阳性与阴性。
  • 该方法可检测急性及陈旧血小板贫乏血栓,并评估纤维蛋白与高铁血红蛋白含量。

关键影像表现/征象

  • TEE阳性组LAA的SUVMax中位4.0(IQR 3.0-6.0),阴性组2.3(IQR 2.1-2.5)。
  • TEE阳性组LAA的T1Min中位970 ms(IQR 780-1080 ms),阴性组1380 ms(IQR 1120-1620 ms),两组间有重叠。

诊断标准与关键数值

  • SUVMax诊断TEE阳性血栓的AUC为0.97。
  • SUVMax阈值2.6时,敏感度100%,特异度84%。
  • SUVMax联合T1Min行逻辑回归,对TEE阳性与阴性分类准确率100%。

临床应用与阅片要点

  • 可无创检测左心耳血栓,尤其适用于TEE不耐受或禁忌者。
  • SUVMax阈值2.6可作为提示血栓的参考界值,但特异度有限需结合T1Min。
  • T1Min在两组间有重叠,不宜单独用于排除血栓。

局限性

  • T1Min在TEE阳性与阴性组间存在重叠,单独诊断价值有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The authors present a novel technique to detect and characterize LAA thrombus in humans using combined positron emission tomography (PET)/cardiac magnetic resonance (CMR) of a fibrin-binding radiotracer, [64Cu]FBP8.

BACKGROUND: The detection of thrombus in the left atrial appendage (LAA) is vital in the prevention of stroke and is currently performed using transesophageal echocardiography (TEE).

METHODS: The metabolism and pharmacokinetics of [64Cu]FBP8 were studied in 8 healthy volunteers. Patients with atrial fibrillation and recent TEEs of the LAA (positive n = 12, negative n = 12) were injected with [64Cu]FBP8 and imaged with PET/CMR, including mapping the longitudinal magnetic relaxation time (T1) in the LAA.

RESULTS: [64Cu]FBP8 was stable to metabolism and was rapidly eliminated. The maximum standardized uptake value (SUVMax) in the LAA was significantly higher in the TEE-positive than TEE-negative subjects (median of 4.0 [interquartile range (IQR): 3.0-6.0] vs 2.3 [IQR: 2.1-2.5]; P < 0.001), with an area under the receiver-operating characteristic curve of 0.97. An SUVMax threshold of 2.6 provided a sensitivity of 100% and specificity of 84%. The minimum T1 (T1Min) in the LAA was 970 ms (IQR: 780-1,080 ms) vs 1,380 ms (IQR: 1,120-1,620 ms) (TEE positive vs TEE negative; P < 0.05), with some overlap between the groups. Logistic regression using SUVMax and T1Min allowed all TEE-positive and TEE-negative subjects to be classified with 100% accuracy.

CONCLUSIONS: PET/CMR of [64Cu]FBP8 is able to detect acute as well as older platelet-poor thrombi with excellent accuracy. Furthermore, the integrated PET/CMR approach provides useful information on the biological properties of thrombus such as fibrin and methemoglobin content. (Imaging of LAA Thrombosis; NCT03830320).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Izquierdo-Garcia D, Désogère P, Philip AL, et al. Detection and Characterization of Thrombosis in Humans Using Fibrin-Targeted Positron Emission Tomography and Magnetic Resonance. JACC Cardiovasc Imaging. 2021. PMID: 34656469. doi:10.1016/j.jcmg.2021.08.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。