文献速递神经CT

多期CTA组织图辅助识别中等血管闭塞

Multiphase CTA-derived tissue maps aid in detection of medium vessel occlusions.
PubMed 文献 · Neuroradiology · 2021-10-19

本研究纳入116例缺血性卒中患者(58例MeVO、58例非MeVO),由两名阅片者盲法评估mCTA组织图判断MeVO及闭塞部位。以基线mCTA专家判读为参考,敏感度91%、特异度82%、AUC 0.87;以CTP图为参考,敏感度87%、特异度78%、AUC 0.83。mCTA与CTP预测梗死体积平均差4.8 mL,Dice系数33.5%。

要点

  • mCTA组织图识别MeVO敏感度91%、特异度82%,可作为快速筛查工具
  • 与CTP图对照敏感度87%、特异度78%,诊断效能接近CTP
  • mCTA与CTP预测梗死体积接近但空间重叠仅中等(Dice 33.5%)

核心结论

  • mCTA组织图可可靠识别MeVO卒中并预测组织转归,诊断效能与CTP相近。

研究设计与样本

  • 单中心回顾性研究,纳入116例缺血性卒中患者(58例MeVO、58例非MeVO),由两名阅片者盲法评估mCTA组织图,参考标准为基线mCTA专家判读与CTP图。

关键影像表现/征象

  • mCTA组织图可判断MeVO有无及闭塞部位,与基线mCTA专家判读一致性良好(kappa 0.72,95%CI 0.60-0.85)。
  • mCTA与CTP预测的最终梗死体积平均差4.8 mL(一致性界限-58.5至68.1),空间重叠Dice系数33.5%。

诊断标准与关键数值

  • 以基线mCTA专家判读为参考:MeVO检出敏感度91%(95%CI 80-97)、特异度82%(95%CI 70-90)、AUC 0.87(95%CI 0.80-0.93)。
  • 以CTP图为参考:敏感度87%(95%CI 75-95)、特异度78%(95%CI 65-88)、AUC 0.83(95%CI 0.76-0.90)。
  • 阅片者间一致性Cohen kappa 0.72(95%CI 0.60-0.85)。

临床应用与阅片要点

  • 对疑似MeVO的卒中患者,可借助mCTA组织图快速定位闭塞血管并提示缺血组织范围,弥补单期CTA对远端血管显示不足。
  • mCTA与CTP预测梗死体积接近但空间重叠仅中等,报告梗死核心或组织窗时应结合CTP等多参数信息,避免单凭mCTA组织图判断。
  • mCTA组织图判读一致性良好,适合作为急诊流程中的辅助筛查工具。

局限性

  • 回顾性设计,样本来自单中心,结论外推需多中心验证。
  • mCTA与CTP预测梗死空间重叠仅中等(Dice 33.5%),组织转归预测的空间准确性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Medium vessel occlusions (MeVOs) can be challenging to detect on imaging. Multiphase computed tomography angiography (mCTA) has been shown to improve large vessel occlusion (LVO) detection and endovascular treatment (EVT) selection. The aims of this study were to determine if mCTA-derived tissue maps can (1) accurately detect MeVOs and (2) predict infarction on 24-h follow-up imaging with comparable accuracy to CT perfusion (CTP).

METHODS: Two readers assessed mCTA tissue maps of 116 ischemic stroke patients (58 MeVOs, 58 non-MeVOs) and determined by consensus: (1) MeVO (yes/no) and (2) occlusion site, blinded to clinical or imaging data. Sensitivity, specificity, and area under the curve (AUC) for MeVO detection were estimated in comparison to reference standards of (1) expert readings of baseline mCTA and (2) CTP maps. Volumetric and spatial agreement between mCTA- and CTP-predicted infarcts was assessed using concordance/intraclass correlation and Dice coefficients. Interrater agreement for MeVO detection on mCTA tissue maps was estimated with Cohen's kappa.

RESULTS: MeVO detection from mCTA-derived tissue maps had a sensitivity of 91% (95% CI: 80-97), specificity of 82% (95% CI: 70-90), and AUC of 0.87 (95% CI: 0.80-0.93) compared to expert reads of baseline mCTA. Interrater reliability was good (0.72, 95% CI: 0.60-0.85). Compared to CTP maps, sensitivity was 87% (95% CI: 75-95), specificity was 78% (95%CI: 65-88), and AUC was 0.83 (95% CI: 0.76-0.90). The mean difference between mCTA- and CTP-predicted final infarct volume was 4.8 mL (limits of agreement: - 58.5 to 68.1) with a Dice coefficient of 33.5%.

CONCLUSION: mCTA tissue maps can be used to reliably detect MeVO stroke and predict tissue fate.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. McDonough RV, Qiu W, Ospel JM, et al. Multiphase CTA-derived tissue maps aid in detection of medium vessel occlusions. Neuroradiology. 2021. PMID: 34668040. doi:10.1007/s00234-021-02830-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。