文献速递神经介入MR

急性缺血性卒中机械取栓患者的SWI磁敏感血管征

SWI Susceptibility Vessel Sign in Patients Undergoing Mechanical Thrombectomy for Acute Ischemic Stroke.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-09-30

该回顾性研究分析577例接受机械取栓的急性缺血性卒中患者,评估SWI磁敏感血管征的出现率及其与介入和临床结局的关联。结果显示87.5%患者存在该征,与串联闭塞及成功再灌注相关,并独立关联90天功能独立和更低死亡率,但不影响取栓次数、首过再灌注或并发症风险。

要点

  • SWI磁敏感血管征在取栓患者中常见(87.5%),提示血栓负荷。
  • 该征与串联闭塞(aOR 3.3)及成功再灌注(aOR 2.4)相关。
  • 该征独立关联90天功能独立(aOR 2.1)和更低死亡率(aOR 0.4)。

核心结论

  • SWI磁敏感血管征是急性缺血性卒中取栓患者中常见的MR成像现象,与成功再灌注相关。
  • 该征与90天功能独立和更低死亡率独立相关,但不能完全归因于更高的再灌注率。

研究设计与样本

  • 使用1.5T或3T MR成像,采用多变量logistic回归分析,结果以调整OR及95%CI表示。

关键影像表现/征象

  • SWI磁敏感血管征表现为血管内磁敏感信号,在87.5%(n=505)患者中存在。

临床应用与阅片要点

  • 阅片时注意识别SWI上的磁敏感血管征,可提示血栓位置及串联闭塞可能。
  • 该征预示更高的成功再灌注概率及更好的临床结局,可作为预后参考。
  • 该征不影响取栓次数、首过再灌注或围手术期并发症风险,不应据此改变取栓策略。

局限性

  • 回顾性研究设计。
  • 单中心研究。
  • 仅纳入接受机械取栓的患者,存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The frequency and clinical significance of the susceptibility vessel sign in patients with acute ischemic stroke remains unclear. We aimed to assess its prevalence in patients with acute ischemic stroke undergoing mechanical thrombectomy and to analyze its association with interventional and clinical outcome parameters in that group.

MATERIALS AND METHODS: Six hundred seventy-six patients with acute ischemic stroke and admission MR imaging were reviewed retrospectively. Of those, 577 met the eligibility criteria for further analysis. Imaging was performed using a 1.5T or 3T MR imaging scanner. Associations between baseline variables, interventional and clinical outcome parameters, and susceptibility vessel sign were determined with multivariable logistic regression models. Results are shown as adjusted ORs with 95% CIs.

RESULTS: The susceptibility vessel sign was present in 87.5% (n = 505) of patients and associated with tandem occlusion (adjusted OR, 3.3; 95% CI, 1.1-10.0; P = .032) as well as successful reperfusion, defined as an expanded TICI score of ≥2b (adjusted OR, 2.4; 95% CI, 1.28-4.6; P = .007). The susceptibility vessel sign was independently associated with functional independence (mRS ≤ 2: adjusted OR, 2.1; 95% CI, 1.1-4.0; P = .028) and lower mortality (adjusted OR, 0.4; 95% CI, 0.2-0.7; P = .003) at 90 days, even after adjusting for successful reperfusion. The susceptibility vessel sign did not influence the number of passes performed during mechanical thrombectomy, the first-pass reperfusion, or the risk of peri- or postinterventional complications.

CONCLUSIONS: The susceptibility vessel sign is an MR imaging phenomenon frequently observed in patients with acute ischemic stroke and is associated with successful reperfusion after mechanical thrombectomy. However, superior clinical functional outcome and lower mortality noted in patients showing the susceptibility vessel sign could not be entirely attributed to higher reperfusion rates.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。