螺旋2D T2加权TSE脑MR成像:初步临床经验
螺旋序列扫描时间较笛卡尔和MultiVane分别缩短51.9%和21.9%,在整体图像质量、运动伪影和主观偏好上优于笛卡尔序列,且病灶检出与其余序列一致。
要点
- 螺旋2D T2WI TSE可在2分12秒内完成全脑结构成像,病灶检出与常规序列一致。
- 螺旋与MultiVane在整体图像质量、运动伪影和主观偏好上均优于笛卡尔序列。
- 三种序列在搏动伪影、灰白质分化和病灶 conspicuity 上表现相似。
关键影像表现/征象
- 螺旋序列扫描时间较笛卡尔序列缩短51.9%,较MultiVane序列缩短21.9%。
- 所有序列检出的病灶数量和位置一致。
- 螺旋和MultiVane在整体图像质量、运动伪影存在和主观偏好方面优于笛卡尔序列(P < .001)。
- 三种序列在搏动伪影、灰白质分化和病灶显示方面表现相似(P > .15)。
- 螺旋和MultiVane在WM变异系数和SNR方面优于笛卡尔序列(P < .01)。
临床应用与阅片要点
- 螺旋2D T2WI TSE可作为常规脑结构成像的快速替代序列,尤其适用于需要缩短扫描时间或减少运动伪影的患者。
- 阅片时注意螺旋序列与常规序列病灶检出一致,但需结合整体图像质量评估。
局限性
- 仅使用1.5T MR扫描仪,未评估其他场强设备。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Spiral MR imaging may enable improved image quality and higher scan speeds than Cartesian trajectories. We sought to compare a novel spiral 2D T2-weighted TSE sequence with a conventional Cartesian and an artifact-robust, non-Cartesian sequence named MultiVane for routine clinical brain MR imaging.
MATERIALS AND METHODS: Thirty-one patients were scanned with all 3 sequences (Cartesian, 4 minutes 14 seconds; MultiVane, 2 minutes 49 seconds; spiral, 2 minutes 12 seconds) on a standard clinical 1.5T MR scanner. Three readers described the presence and location of abnormalities and lesions and graded images qualitatively in terms of overall image quality, the presence of motion and pulsation artifacts, gray-white matter differentiation, lesion conspicuity, and subjective preference. Image quality was objectivized by measuring the SNR and the coefficients of variation for CSF, GM, and WM.
RESULTS: Spiral achieved a scan time reduction of 51.9% and 21.9% compared with Cartesian and MultiVane, respectively. The number and location of lesions were identical among all sequences. As for the qualitative analysis, interreader agreement was high (Krippendorff α > .75). Spiral and MultiVane both outperformed the Cartesian sequence in terms of overall image quality, the presence of motion artifacts, and subjective preference (P < .001). In terms of the presence of pulsation artifacts, gray-white matter differentiation, and lesion conspicuity, all 3 sequences performed similarly well (P > .15). Spiral and MultiVane outperformed the Cartesian sequence in coefficient of variation WM and SNR (P < .01).
CONCLUSIONS: Spiral 2D T2WI TSE is feasible for routine structural brain MR imaging and offers high-quality, artifact-robust brain imaging in short scan times.
引用
- Sartoretti E, Sartoretti-Schefer S, van Smoorenburg L, et al. Spiral 2D T2-Weighted TSE Brain MR Imaging: Initial Clinical Experience. AJNR Am J Neuroradiol. 2021. PMID: 34674994. doi:10.3174/ajnr.A7299