文献速递腹部MR

基于深度学习的超分辨率算法用于1.5T腹部部分傅里叶梯度回波序列:缩短屏气时间并提高图像质量

Analysis of a Deep Learning-Based Superresolution Algorithm Tailored to Partial Fourier Gradient Echo Sequences of the Abdomen at 1.5 T: Reduction of Breath-Hold Time and Improvement of Image Quality.
PubMed 文献 · Invest Radiol · 2022-01-01

VIBESR采用更激进的部分傅里叶设置,理论采集时间从15±1秒缩短至13±1秒,两位放射科医生独立盲法评估显示VIBESR在噪声、血管及器官清晰度对比度、诊断信心方面均更优(P<0.001)。

要点

  • VIBESR重建可缩短理论采集时间,同时提升图像质量与诊断信心。
  • 两位阅片者均认为VIBESR噪声水平更佳(中位4 vs 3,P<0.001)。
  • 血管、器官及淋巴结的清晰度和对比度VIBESR均优于常规VIBE。

关键影像表现/征象

  • VIBESR噪声水平中位评分为4(4-4),优于VIBEStd的3(3-3)(P<0.001)。
  • VIBESR血管、器官及淋巴结的清晰度和对比度中位评分为4(4-4),优于VIBEStd的3(3-3)(P<0.001)。
  • 阅片者1诊断信心中位评分VIBESR为4(4-4),VIBEStd为3.5(3-4);阅片者2两者均为4(4-4)(均P<0.001)。

诊断标准与关键数值

  • 采用Likert 1-4分评估噪声、血管清晰度/对比度、器官及淋巴结清晰度/对比度、整体图像质量、诊断信心和病灶可见性,4分为最佳。
  • 常规VIBEStd平均采集时间为15±1秒,VIBESR重建所用数据理论采集时间为13±1秒。

临床应用与阅片要点

  • 在日常腹部增强MRI中,可采用深度学习超分辨率联合更激进的部分傅里叶设置以缩短屏气时间。
  • 重建图像在噪声和结构清晰度方面表现更优,有助于提升诊断信心。

局限性

  • 理论采集时间缩短基于回顾性重建,未实际前瞻性验证扫描时间缩短效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to investigate the feasibility and impact of a novel deep learning superresolution algorithm tailored to partial Fourier allowing retrospectively theoretical acquisition time reduction in 1.5 T T1-weighted gradient echo imaging of the abdomen.

MATERIALS AND METHODS: Fifty consecutive patients who underwent a 1.5 T contrast-enhanced magnetic resonance imaging examination of the abdomen between April and May 2021 were included in this retrospective study. After acquisition of a conventional T1-weighted volumetric interpolated breath-hold examination using Dixon for water-fat separation (VIBEStd), the acquired data were reprocessed including a superresolution algorithm that was optimized for partial Fourier acquisitions (VIBESR). To accelerate theoretically the acquisition process, a more aggressive partial Fourier setting was applied in VIBESR reconstructions practically corresponding to a shorter acquisition for the data included in the retrospective reconstruction. Precontrast, dynamic contrast-enhanced, and postcontrast data sets were processed. Image analysis was performed by 2 radiologists independently in a blinded random order without access to clinical data regarding the following criteria using a Likert scale ranging from 1 to 4 with 4 being the best: noise levels, sharpness and contrast of vessels, sharpness and contrast of organs and lymph nodes, overall image quality, diagnostic confidence, and lesion conspicuity.Wilcoxon signed rank test for paired data was applied to test for significance.

RESULTS: Mean patient age was 61 ± 14 years. Mean acquisition time for the conventional VIBEStd sequence was 15 ± 1 seconds versus theoretical 13 ± 1 seconds of acquired data used for the VIBESR reconstruction. Noise levels were evaluated to be better in VIBESR with a median of 4 (4-4) versus a median of 3 (3-3) in VIBEStd by both readers (P < 0.001). Sharpness and contrast of vessels as well as organs and lymph nodes were also evaluated to be superior in VIBESR compared with VIBEStd with a median of 4 (4-4) versus a median of 3 (3-3) (P < 0.001). Diagnostic confidence was also rated superior in VIBESR with a median of 4 (4-4) versus a median of 3.5 (3-4) in VIBEStd by reader 1 and with a median of 4 (4-4) for VIBESR and a median of 4 (4-4) for VIBEStd by reader 2 (both P < 0.001).

CONCLUSIONS: Image enhancement using deep learning-based superresolution tailored to partial Fourier acquisitions of T1-weighted gradient echo imaging of the abdomen provides improved image quality and diagnostic confidence in combination with more aggressive partial Fourier settings leading to shorter scan time.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Afat S, Wessling D, Afat C, et al. Analysis of a Deep Learning-Based Superresolution Algorithm Tailored to Partial Fourier Gradient Echo Sequences of the Abdomen at 1.5 T: Reduction of Breath-Hold Time and Improvement of Image Quality. Invest Radiol. 2022. PMID: 34510101. doi:10.1097/RLI.0000000000000825

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。