三维经会阴盆底超声记录中裂孔尺寸的自动提取
本研究开发了一种基于卷积神经网络的自动软件工具,用于在三维经会阴超声(TPUS)容积中检测C平面并分割提肛肌裂孔。使用73个TPUS容积测试,自动方法与两位专家手动勾画结果相似,裂孔面积在观察者内变异范围内,C平面检测精度5.76±5.06°和6.46±5.18mm,优于观察者间变异;自动分析平均时间35±4秒,手动为2分35±17秒。
要点
- 自动工具可在TPUS容积中自动检测C平面并分割提肛肌裂孔,结果与专家手动测量相似。
- 自动方法C平面检测误差为5.76±5.06°和6.46±5.18mm,小于观察者间变异9.39±6.21°和8.48±6.62mm。
- 自动分析耗时35±4秒,较手动2分35±17秒显著缩短。
核心结论
- 自动方法在TPUS容积中测量提肛肌裂孔面积的结果与专家手动测量相似,裂孔面积在观察者内变异范围内,C平面检测精度优于观察者间变异,视觉图灵测试提示自动方法识别C平面位置与专家相当,且减少分析时间和所需专业知识。
研究设计与样本
- 研究论文;使用73个代表性TPUS容积测试自动管道,以两位专家手动勾画的裂孔轮廓为参考,比较自动与手动方法。
诊断标准与关键数值
- C平面检测精度以角度和欧氏距离评估:自动方法5.76±5.06°和6.46±5.18mm,观察者间变异9.39±6.21°和8.48±6.62mm;裂孔面积自动与专家测量在观察者内变异范围内;采用Hausdorff距离、面积、临床质量评分、C平面角度和欧氏距离评估。
临床应用与阅片要点
- 自动工具可能减少盆底障碍评估所需时间和专业知识;作者认为该解决方案准确、相对快速、稳健可靠。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aims of this work were to create a robust automatic software tool for measurement of the levator hiatal area on transperineal ultrasound (TPUS) volumes and to measure the potential reduction in variability and time taken for analysis in a clinical setting. The proposed tool automatically detects the C-plane (i.e., the plane of minimal hiatal dimensions) from a 3-D TPUS volume and subsequently uses the extracted plane to automatically segment the levator hiatus, using a convolutional neural network. The automatic pipeline was tested using 73 representative TPUS volumes. Reference hiatal outlines were obtained manually by two experts and compared with the pipeline's automated outlines. The Hausdorff distance, area, a clinical quality score, C-plane angle and C-plane Euclidean distance were used to evaluate C-plane detection and quantify levator hiatus segmentation accuracy. A visual Turing test was created to compare the performance of the software with that of the expert, based on the visual assessment of C-plane and hiatal segmentation quality. The overall time taken to extract the hiatal area with both measurement methods (i.e., manual and automatic) was measured. Each metric was calculated both for computer-observer differences and for inter-and intra-observer differences. The automatic method gave results similar to those of the expert when determining the hiatal outline from a TPUS volume. Indeed, the hiatal area measured by the algorithm and by an expert were within the intra-observer variability. Similarly, the method identified the C-plane with an accuracy of 5.76 ± 5.06° and 6.46 ± 5.18 mm in comparison to the inter-observer variability of 9.39 ± 6.21° and 8.48 ± 6.62 mm. The visual Turing test suggested that the automatic method identified the C-plane position within the TPUS volume visually as well as the expert. The average time taken to identify the C-plane and segment the hiatal area manually was 2 min and 35 ± 17 s, compared with 35 ± 4 s for the automatic result. This study presents a method for automatically measuring the levator hiatal area using artificial intelligence-based methodologies whereby the C-plane within a TPUS volume is detected and subsequently traced for the levator hiatal outline. The proposed solution was determined to be accurate, relatively quick, robust and reliable and, importantly, to reduce time and expertise required for pelvic floor disorder assessment.
引用
- Williams H, Cattani L, Van Schoubroeck D, et al. Automatic Extraction of Hiatal Dimensions in 3-D Transperineal Pelvic Ultrasound Recordings. Ultrasound Med Biol. 2021. PMID: 34538535. doi:10.1016/j.ultrasmedbio.2021.08.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。