增强现实技术辅助介入放射学中天花板悬挂辐射防护屏正确使用的教学应用开发与评估
本研究开发了一款增强现实(AR)应用,用于帮助介入放射学(IR)医务人员学习正确使用天花板悬挂辐射防护屏,并通过AR可视化三种设置下血管造影室的散射辐射分布。33名医务人员使用该应用后填写基于ARCS动机模型的IMMS问卷,总体评分为4.67±0.30(5分制),医师在注意力、相关性和满意度维度得分略低于其他医务人员(无统计学显著性)。结论认为该AR应用在学习者动机方面获得高度评价。
要点
- AR应用可视化正确与错误使用防护屏时的散射辐射分布,有助培训。
- 33名医务人员使用后IMMS总均分4.67±0.30,动机评价高。
- 医师在注意力、相关性、满意度维度得分略低但无统计学差异。
临床应用与阅片要点
- 可利用AR可视化散射辐射分布,辅助介入人员理解防护屏正确摆放位置。
- 培训中可针对医师群体在注意力、相关性、满意度方面加强引导。
局限性
- 研究仅评估学习者动机(IMMS问卷),未评估实际防护效果或患者剂量。
- 样本量33名医务人员,医师与其他人员得分差异未达统计学显著。
- 单中心、非随机设计,缺乏对照教学方式比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: An augmented reality (AR) application to help medical staff involved in interventional radiology (IR) learn how to properly use ceiling-suspended radiation shielding screens was created, and its utility was tested from the perspective of learner motivation.
METHOD: The distribution of scattered radiation in an angiography room was visualized with an AR application in three settings: when a ceiling-suspended radiation shielding screen is not used (incorrect); when there is a gap between the bottom edge of the shielding screen and the patient's torso (incorrect); and when there is no gap between the bottom edge of the shielding screen and the patient's torso (correct). This AR application was used by 33 medical staff, after which an Instructional Materials Motivation Survey (IMMS) based on the John Keller's ARCS (four categories of Attention, Relevance, Confidence, and Satisfaction) Motivation Model, consisting of 36-items with responses on a 5-point (1-5) Likert scale, was conducted.
RESULTS: The overall score was a high 4.67 ± 0.30 (mean ± standard deviation). Physician's scores tended to be lower than those of other medical staff in the categories of Attention, Relevance, and Satisfaction (not statistically significant).
CONCLUSIONS: The AR application to learn how to properly use ceiling-suspended radiation shielding screens was highly rated from the perspective of learner motivation.
引用
- Matsuzaki S, Moritake T, Morota K, et al. Development and assessment of an educational application for the proper use of ceiling-suspended radiation shielding screens in angiography rooms using augmented reality technology. Eur J Radiol. 2021. PMID: 34482175. doi:10.1016/j.ejrad.2021.109925
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。