肠腔直径比诊断HD的AUC为0.969(95%CI 0.936-1.000),截断值1.51时敏感度89.8%、特异度96.3%。以肠腔直径比为主要标准联合两项次要标准,敏感度91.8%、特异度96.3%,与造影灌肠一致性极佳(kappa 0.825)。

要点

  • 肠腔直径比是诊断HD最优的单参数,截断值1.51。
  • 联合主要与次要标准后敏感度91.8%、特异度96.3%。
  • 水灌肠超声与造影灌肠诊断一致性极佳(kappa 0.825)。

核心结论

  • 水灌肠超声对高度怀疑HD的儿童便秘患者具有高敏感度和高特异度,可同时评估结肠形态与血供,与造影灌肠相关性好,在合适条件下可作为替代筛查方法。

关键影像表现/征象

  • 评估内容包括扩张段、狭窄段、肠腔直径比、移行区、肠壁增厚及上游肠管血流灌注。
  • 肠腔直径比在各项参数中诊断效能最优。

诊断标准与关键数值

  • 肠腔直径比诊断HD的AUC为0.969(95%CI 0.936-1.000),截断值1.51,敏感度89.8%、特异度96.3%。
  • 以肠腔直径比为主要标准联合两项次要标准,水灌肠超声敏感度91.8%、特异度96.3%,造影灌肠敏感度91.8%、特异度87%,差异无统计学意义(p=0.063)。
  • 水灌肠超声与造影灌肠诊断一致性kappa值为0.825(p<0.001)。

临床应用与阅片要点

  • 对高度怀疑HD的便秘患儿,可优先测量肠腔直径比并以1.51为截断值辅助判断。
  • 联合肠腔直径比与移行区、肠壁增厚、上游血流等次要标准可提高诊断特异度。
  • 水灌肠超声可同时评估结肠形态与血供,可作为造影灌肠的替代或补充手段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare hydrocolonic sonography with histopathology for diagnosing children with symptoms highly suggestive of Hirschsprung disease (HD).

METHODS: In this prospective study, patients presenting refractory constipation highly suggestive of HD underwent hydrocolonic sonography with retrograde infusion of saline into the colon. The dilated segments, narrowed segments, luminal diameter ratio, transition zone (TZ), thickening, and blood perfusion of the upstream bowel were evaluated. The sensitivity and specificity of combined and single parameters were determined in comparison with biopsy.

RESULTS: One hundred and three children were included in this study; 49 were confirmed to have HD. The luminal diameter ratio showed superiority over other parameters. An area under the curve (AUC) of 0.969 (95% confidence interval [CI]: 0.936-1.000) and a cutoff value of 1.51 were established by receiver operating characteristic (ROC) curve analysis of the luminal diameter ratio (sensitivity: 89.8%; specificity: 96.3%). By combining the luminal diameter ratio as the major criterion with two minor criteria, hydrocolonic sonography showed the same sensitivity (91.8%) and better specificity (96.3% vs 87%) than contrast enema, but this difference was not statistically significant (p = 0.063). Consistency analysis showed a kappa value of 0.825 (p < 0.001), indicating excellent agreement between hydrocolonic sonography and contrast enema.

CONCLUSIONS: Hydrocolonic sonography is a valuable diagnostic tool with both high sensitivity and specificity for HD diagnosis, allowing morphological and vascular assessments of the colon, and correlates well with contrast enema. In the appropriate setting, hydrocolonic sonography may be an alternative screening method for HD in a large group of children with constipation. Key Points • Hydrocolonic sonography is a simple, well-tolerated diagnostic tool with both high sensitivity and specificity for HD diagnosis. • Hydrocolonic sonography allows morphological and vascular assessments of the colon, and correlates well with contrast enema. • Hydrocolonic sonography is a possible alternative modality for paediatric patients highly suggestive of HD.