文献速递技术与安全CTDR

简化质子束治疗中的图像引导放疗流程

Streamlining the image-guided radiotherapy process for proton beam therapy.
PubMed 文献 · Br J Radiol · 2021-09-14

该研究评估了英国首个质子束治疗中心的治疗中成像工作流程,旨在减少成像时间和患者不必要的成像剂量。研究分析了前20例患者(70%儿童,30%青少年/成人)的229次治疗 session,发现初始2DkV图像后仅8.3%的分次需要重新定位,而三步流程比两步流程平均每患者增加3.4 mGy成像剂量和5.1分钟治疗床时间。2DkV与CBCT的平均位移高度相关(R=0.94, 0.94, 0.80),Bland-Altman分析显示偏倚很小且一致性界限窄,因此取消初始2DkV、简化为两步流程已被实施为标准验证方案。

要点

  • 三步IGPBT流程中初始2DkV仅8.3%分次需重新定位,提示多数情况多余。
  • 取消初始2DkV可减少每患者平均3.4 mGy成像剂量和5.1分钟治疗床时间。
  • 2DkV与CBCT位移高度相关(R=0.94/0.94/0.80),支持简化流程。

局限性

  • 单中心、小样本(20例患者)回顾性研究。
  • 未报告其他中心的外部验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This work evaluated the on-treatment imaging workflow in the UK's first proton beam therapy (PBT) centre, with a view to reducing times and unnecessary imaging doses to patients.

METHODS: Imaging dose and timing data from the first 20 patients (70% paediatrics, 30% TYA/adult) treated with PBT using the initial image-guided PBT (IGPBT) workflow of a 2-dimensional kilo-voltage (2DkV), followed by cone-beam computed-tomography (CBCT) and repeat 2DkV was included. Pearson correlations and Bland-Altman analysis were used to describe correlations between 2DkV and CBCT images to determine if any images were superfluous.

RESULTS: 229 treatment sessions were evaluated. Patient repositioning following the initial 2DkV (i2DkV) was required on 19 (8.3%) fractions. This three-step process resulted in an additional mean imaging dose of 3.4 mGy per patient, and 5.1 minutes on the treatment bed for the patient, over a whole course of PBT, compared to a two-step workflow (removing the i2DkV image). Correspondence between the mean displacements from i2DkV and CBCT was high, with R = 0.94, 0.94 and 0.80 in the anteroposterior, superiorinferior and right-left directions, respectively. Bland-Altman analysis showed very little bias and narrow limits of agreement.

CONCLUSIONS: Removing the i2DkV, streamlining to a two-step workflow, would reduce treatment times and imaging dose, and has been implemented as standard verification protocol. For challenging cases (e.g. paediatric patients under GA), further investigations are required before the three-step workflow can be modified.

ADVANCES IN KNOWLEDGE: This is the first report assessing a preliminary imaging protocol in PBT in the UK and determining a way to reduce dose and time, which ultimately benefits the patient.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Davies LSC, McHugh L, Aznar M, et al. Streamlining the image-guided radiotherapy process for proton beam therapy. Br J Radiol. 2021. PMID: 34520675. doi:10.1259/bjr.20210764

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。