文献速递神经儿科影像CT

三维容积渲染CT改善脑室分流管断裂检测

Improving the detection of ventricular shunt disruption using volume-rendered three-dimensional head computed tomography.
PubMed 文献 · Pediatr Radiol · 2021-09-17

本文为儿科影像 pictorial essay,讨论如何生成三维容积渲染CT图像以评估儿童脑脊液分流管的完整性。文章指出,二维多平面CT图像可能漏诊细微的分流管断裂,尤其是断裂位于成像平面内时;三维容积渲染可快速直观地评估颅外分流管完整性。文中提供了多个诊断分流管断裂的示例,并讨论了该技术的潜在陷阱及避免方法。

要点

  • 三维容积渲染CT可直观评估颅外分流管完整性,减少二维图像漏诊。
  • 怀疑分流管功能异常时,除观察脑室大小变化外需仔细追踪分流管走行。
  • 细微断裂在二维图像上可能因位于成像平面内而漏诊,三维重建有助显示。

关键影像表现/征象

  • 二维多平面CT图像上,细微的分流管断裂可能被漏诊,尤其是当断裂位于成像平面内时。
  • 三维容积渲染图像可将视野内的颅外分流管显示为三维对象,便于直观评估其完整性。

临床应用与阅片要点

  • 对于怀疑脑脊液分流管功能异常的儿童,除评估脑室大小变化外,应仔细审查CT图像以确认所显示分流管部分的完整性。
  • 利用三维容积渲染图像可快速直观地评估颅外分流管,减少二维图像上因平面内断裂导致的漏诊。
  • 需注意该技术的潜在陷阱并采取相应方法避免。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Hydrocephalus is the most common neurosurgical disorder in children, and cerebrospinal fluid (CSF) diversion with shunt placement is the most commonly performed pediatric neurosurgical procedure. CT is frequently used to evaluate children with suspected CSF shunt malfunction to assess change in ventricular size. Moreover, careful review of the CT images is important to confirm the integrity of the imaged portions of the shunt system. Subtle shunt disruptions can be missed on multiplanar two-dimensional (2-D) CT images, especially when the disruption lies in the plane of imaging. The use of volume-rendered CT images enables radiologists to view the extracranial shunt tubing within the field of view as a three-dimensional (3-D) object. This allows for a rapid and intuitive method of assessing the integrity of the extracranial shunt tubing. The purpose of this pictorial essay is to discuss how volume-rendered CT images can be generated to evaluate CSF shunts in the pediatric population and to provide several examples of their utility in diagnosing shunt disruption. We also address the potential pitfalls of this technique and ways to avoid them.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Oztek MA, Parisi MT, Perez FA, et al. Improving the detection of ventricular shunt disruption using volume-rendered three-dimensional head computed tomography. Pediatr Radiol. 2021. PMID: 34535807. doi:10.1007/s00247-021-05190-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。