膝关节骨关节炎定量超声评估滑膜炎、半月板突出和骨赘的信度及与MRI的收敛效度
结果显示骨赘、半月板突出和滑膜炎的组间信度优良(ICC 0.86-0.96),与MRI相关性很强(ICC 0.85-0.98),但外侧半月板突出相关性较低(ICC 0.66),绝对一致性仅内侧胫股间室病变较好。
要点
- 定量超声测量骨赘、半月板突出和滑膜炎的组间信度优良,可用于临床随访。
- 超声与MRI在骨赘、内侧半月板突出和滑膜炎上相关性很强,但外侧半月板突出相关性中等。
- 绝对一致性仅内侧骨赘和内侧半月板突出较好,解读外侧病变时需谨慎。
局限性
- 仅纳入膝骨关节炎患者,未涉及其他人群。
- 外侧半月板突出与MRI相关性及绝对一致性较低,提示超声测量外侧半月板突出可靠性有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIMS: To determine: 1) inter-rater reliability of quantitative measurements of ultrasound-detected synovitis, meniscal extrusion, and osteophytes; and 2) construct (convergent) validity via correlations and absolute agreements between ultrasound- and gold-standard magnetic resonance imaging (MRI)-outcomes in knee osteoarthritis.
METHODS: Dynamic ultrasound images for supra-patellar synovitis, meniscal extrusion, and osteophytes were acquired and quantified by a physician operator, musculoskeletal ultrasonographer, and medical student independently. On the same day, 3T MRI images were acquired. Effusion-synovitis, meniscal extrusion, and osteophytes were quantified on sagittal or coronal proton-density-weighted fat-suppressed noncontrast TSE sequences, respectively. Intra-class correlation coefficients (ICCs), Pearson's correlations (r), and Bland-Altman plots were used to analyze inter-rater reliability, and correlations, and agreements between the two imaging modalities.
RESULTS: Eighty-nine participants [48 females (53.9%)] with mean (standard deviation) age of 61.5 ± 6.9 years were included. The inter-rater reliability was excellent for osteophytes (ICC range = 0.90-0.96), meniscal extrusion (ICC range = 0.90-0.93), and synovitis (ICC range = 0.86-0.88). The correlations between ultrasound pathologies and their MRI counterparts were very strong (ICC range = 0.85-0.98) except for lateral meniscal extrusion [0.66 (95% CI, 0.52-0.76)]. Bland-Altman plots showed 0.01, 0.05, 0.10, 0.53, and 0.60 mm larger size in ultrasound medial tibial and medial femoral osteophytes, medial meniscal extrusions, synovitis, and lateral meniscal extrusions with 95% limits of agreements [±0.39, ±0.44, ±0.85, ±0.70, and ±0.90 (SDs)] than MRI measures, respectively. The lines of equality were within 95% CI of the mean differences (bias) only for medial osteophytes and medial meniscal extrusion.
CONCLUSION: The quantitative assessment of synovitis, meniscal extrusion, and osteophytes generally showed excellent inter-rater reliability and strong correlations with MRI-based measurements. Absolute agreement was strong for medial tibiofemoral pathologies.
引用
- Oo WM, Linklater JM, Bennell KL, et al. Reliability and Convergent Construct Validity of Quantitative Ultrasound for Synovitis, Meniscal Extrusion, and Osteophyte in Knee Osteoarthritis With MRI. J Ultrasound Med. 2021. PMID: 34569080. doi:10.1002/jum.15840
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。