数字化断层合成与常规X线摄影评估股骨头坏死的比较
本研究以CT为标准,比较数字化断层合成(DTS)与常规X线摄影检测股骨头坏死(ONFH)的诊断性能及可重复性。45例临床疑似ONFH患者行正位X线、DTS和CT检查,两名肌骨放射科医师独立评估。DTS的敏感度(89.4%-100% vs. 74.5%-76.6%)和特异度(97.3%-100% vs. 78.4%-83.8%)均高于X线,观察者间和观察者内一致性也更高。
要点
- DTS检测ONFH的敏感度89.4%-100%、特异度97.3%-100%,均高于常规X线的74.5%-76.6%和78.4%-83.8%。
- DTS识别ONFH亚型的观察者间一致性κ=0.86(优),常规X线κ=0.57(中等)。
- DTS观察者内一致性κ=0.96,高于常规X线的κ=0.69。
核心结论
- DTS检测ONFH的诊断性能和可重复性均高于常规X线摄影,作者认为DTS可能作为疑似ONFH患者的一线诊断方法替代X线摄影。
研究设计与样本
- 以CT为标准,比较DTS与常规X线摄影诊断性能的研究;45例临床疑似ONFH患者(24男21女,年龄25-77岁)行正位X线、DTS和CT检查,两名肌骨放射科医师独立评估ONFH presence和分型,用Cohen's kappa分析观察者间和观察者内一致性。
诊断标准与关键数值
- DTS检测ONFH的敏感度89.4%-100%、特异度97.3%-100%;常规X线摄影敏感度74.5%-76.6%、特异度78.4%-83.8%。DTS识别ONFH亚型优于X线,其中一名读者达统计学显著:1型100% vs. 30.8%(p=0.004),II型97.1% vs. 73.5%(p=0.008)。观察者间一致性DTS κ=0.86、X线κ=0.57;观察者内一致性DTS κ=0.96、X线κ=0.69。
临床应用与阅片要点
- 作者认为DTS可能作为疑似ONFH患者的一线诊断方法替代常规X线摄影;阅片时DTS对ONFH分型的识别和一致性优于X线。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS.
MATERIALS AND METHODS: Forty-five patients (24 male and 21 female; age range, 25-77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen's kappa.
RESULTS: DTS had higher sensitivity (89.4%-100% vs. 74.5%-76.6%) and specificity (97.3%-100% vs. 78.4%-83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively).
CONCLUSION: DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.
引用
- Roh YH, Lee S, Ryu JA, et al. Digital Tomosynthesis versus Conventional Radiography for Evaluating Osteonecrosis of the Femoral Head. Korean J Radiol. 2021. PMID: 34564962. doi:10.3348/kjr.2021.0058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。