文献速递甲状腺与浅表儿科影像US

剪切波弹性成像评估儿童青少年弥漫性甲状腺疾病信度

Reliability of shear wave elastography in the evaluation of diffuse thyroid diseases in children and adolescents.
PubMed 文献 · Eur J Radiol · 2021-08-30

前瞻性研究纳入74例弥漫性甲状腺疾病(DTD)患者和20名健康对照,行常规超声、多普勒及剪切波弹性成像(SWE)。结果显示正常组与DTD组及不同类型DTD间SWE均值差异有统计学意义,SWE鉴别正常甲状腺与DTD及DTD亚型的最佳截断值分别为12.8、17.8、13.4、13.9 kPa。

要点

  • SWE可用于区分正常甲状腺与弥漫性甲状腺疾病。
  • SWE可鉴别桥本甲状腺炎与Graves病,最佳截断值17.8 kPa。
  • SWE鉴别桥本甲状腺炎与单纯性甲状腺肿截断值13.4 kPa。

核心结论

  • SWE是鉴别正常甲状腺组织与弥漫性甲状腺疾病以及区分不同弥漫性甲状腺疾病类型的可靠诊断工具。

研究设计与样本

  • 前瞻性研究纳入74例弥漫性甲状腺疾病患者和20名健康对照,均行临床评估、实验室检查、常规超声及多普勒检查后行SWE评估。

关键影像表现/征象

  • 正常对照组、单纯性甲状腺肿、桥本甲状腺炎和Graves病的SWE均值分别为10.9±1.78、12.8±2.1、15.31±2.95和17.26±4.2 kPa。

诊断标准与关键数值

  • SWE鉴别正常甲状腺与弥漫性甲状腺疾病的最佳截断值为12.8 kPa。
  • SWE鉴别桥本甲状腺炎与Graves病的最佳截断值为17.8 kPa。
  • SWE鉴别桥本甲状腺炎与单纯性甲状腺肿的最佳截断值为13.4 kPa。
  • SWE鉴别Graves病与单纯性甲状腺肿的最佳截断值为13.9 kPa。

临床应用与阅片要点

  • 在儿童青少年弥漫性甲状腺疾病评估中,可参考SWE截断值辅助区分正常与病变及不同疾病类型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Thyroid diseases are common yet serious in children that lead to many metabolic and growth disorders; the most common among these are diffuse thyroid diseases (DTD). This study aimed to evaluate the reliability of shear wave elastography (SWE) to differentiate and diagnose DTD from normal thyroid tissue.

METHOD: This prospective study included normal participants and patients with DTD. The subjects were assessed by clinical evaluation, laboratory investigation, conventional ultrasound, and Doppler examination, followed by SWE assessments. Statistical analysis was performed using the t-test and one-way ANOVA test, as appropriate. Receiver operating characteristic (ROC) curves were used to determine the best cutoff values to differentiate healthy participants from those with DTD and to differentiate between different types of DTD.

RESULTS: The study included 74 patients with DTD and 20 healthy participants. The mean SWE values were 10.9 ± 1.78, 12.8 ± 2.1, 15.31 ± 2.95, and 17.26 ± 4.2 kPa for the normal participants and for patients with simple goiter, Hashimoto's thyroiditis (HT), or Grave's disease (GD), respectively. Statistically significant differences were noted between the mean SWE of the normal participants and that of patients with DTD, as well as between the mean SWE of patients with different types of DTD (P < 0.05). The best SWE cutoff values to differentiate a normal thyroid from DTD, HT from GD, HT from simple goiter, and GD from simple goiter were 12.8, 17.8, 13.4, and 13.9 kPa, respectively.

CONCLUSIONS: SWE is a reliable diagnostic tool for differentiating normal thyroid tissue from DTD, as well as for differentiating between different types of DTD.

来源:Eur J Radiol,查看原文。版权归原作者所有。