超微血管成像与虚拟触诊组织成像量化在甲状腺癌分类中的增量价值
结果显示SMI血流分级和VTIQ剪切波速度在良恶性结节间均有显著差异,三种方法联合的AUC最高(0.9811)。
要点
- 恶性结节SMI血流分级3级占比53.5%,良性结节为29.5%,差异有统计学意义(p<0.001)。
- 恶性结节SWS均值3.97±1.34 m/s,良性结节2.65±0.42 m/s,各SWS参数差异均有统计学意义(p<0.001)。
- US+SMI+VTIQ联合AUC达0.9811,高于US+VTIQ(0.9747)、US+SMI(0.9032)和单用US(0.8291)。
关键影像表现/征象
- 恶性结节倾向于丰富血流,SMI分级3级者38/71(53.5%),良性结节33/112(29.5%),差异有统计学意义(p<0.001)。
- 恶性结节SWS均值3.97±1.34、最大值4.79±1.70、比值1.25±0.39;良性结节分别为2.65±0.42、2.97±0.46、1.15±0.35。
诊断标准与关键数值
- SMI血流分级中3级(丰富血流)在恶性结节中占53.5%,良性结节中占29.5%。
- 良恶性结节间SWS均值、最大值及比值差异均有统计学意义(所有p值<0.001)。
- US+SMI+VTIQ联合AUC为0.9811(95%CI:0.95529-1.000),US+VTIQ为0.9747(0.94543-1.000),US+SMI为0.9032(0.85345-0.95391),单用US为0.8291(0.76417-0.89403)。
临床应用与阅片要点
- 对常规超声难以定性的甲状腺结节,可加做SMI评估血流分级辅助鉴别。
- VTIQ测量的SWS均值、最大值及比值可作为良恶性鉴别的定量参考。
- 联合SMI与VTIQ可提升诊断信心,但需结合常规超声特征综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This prospective study determined the value added by superb microvascular imaging (SMI) and Virtual Touch imaging quantification (VTIQ) to conventional ultrasonography in classifying malignant and benign thyroid nodules. One hundred eighty-three thyroid nodules (TNs) in 120 patients (112 benign and 71 malignant TNs) were evaluated. SMI revealed noticeable variance between benign and malignant TNs (p < 0.001). Malignant nodules tended to have rich vascularity (grade 3: 38/71, 53.5%) compared with benign nodules (grade 3: 33/112, 29.5%). There is a statistically significant difference between malignant and benign TNs with respect to shear-wave speed (SWS) values (all p values <0.001). The SWS mean, maximum and ratio of malignant nodules were 3.97 ± 1.34, 4.79 ± 1.70 and 1.25 ± 0.39, respectively. The SWS mean, maximum and ratio of benign nodules were 2.65 ± 0.42, 2.97 ± 0.46 and 1.15 ± 0.35, respectively. With respect to area under the curve values, the combined use of SMI or VTIQ improved the diagnostic performance of classifying malignant and benign TNs compared with that of ultrasonography alone. The combination of three modalities achieved the greatest area under the curve values (0.9811, 95% confidence interval: 0.95529-1.000), followed by US + VTIQ (0.9747, 0.94543-1.000), US + SMI (0.9032, 0.85345-0.95391) and ultrasonography (0.8291, 0.76417-0.89403).
引用
- Zhu YC, Zhang Y, Shan J, et al. Added Value of Superb Microvascular Imaging and Virtual Touch Imaging Quantification in Assisting Thyroid Cancer Classification. Ultrasound Med Biol. 2021. PMID: 34489133. doi:10.1016/j.ultrasmedbio.2021.07.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。