文献速递乳腺乳腺X线

人工智能系统辅助放射科医生评估BI-RADS 0乳腺X线摄影的价值

The added value of an artificial intelligence system in assisting radiologists on indeterminate BI-RADS 0 mammograms.
PubMed 文献 · Eur Radiol · 2021-09-15

研究纳入34,654例数字乳腺X线摄影,其中1088例初始BI-RADS 0并随访2年。两名中级放射科医生在AI辅助下重新评估,另四名初级放射科医生分组交叉阅读80例。结果显示AI可帮助中级医生正确识别56%-58%的正常病例,避免不必要的随访,但分别漏诊12例和6例恶性肿瘤,且未漏诊高度恶性肿瘤。

要点

  • AI辅助可使中级放射科医生正确识别56%-58%的正常BI-RADS 0病例,减少不必要随访。
  • AI辅助下漏诊的恶性肿瘤分别为12例和6例,但均非高度恶性肿瘤。
  • AI将初级放射科医生评估BI-RADS 0病变的观察者间信度从0.20提升至0.30。

关键影像表现/征象

  • AI辅助下,两名中级放射科医生分别正确识别351例(56%)和362例(58%)正常病例(BI-RADS 1且无需召回)。
  • 两名中级放射科医生在AI辅助下分别漏诊12例(10例浸润性癌和2例导管原位癌)和6例(浸润性癌)恶性病变,这些漏诊病变均非高度恶性肿瘤。
  • AI系统能够检测出放射科医生在 heterogeneous 和极度致密乳腺中倾向于漏诊的低可疑病变。

诊断标准与关键数值

  • 以随访诊断或活检结果为参考标准评估诊断性能。
  • 初级放射科医生观察者间信度从0.20提升至0.30(p < 0.005)。

局限性

  • 研究为回顾性设计。
  • 仅纳入初始BI-RADS 0并在2年随访中被召回的病例,可能存在选择偏倚。
  • AI辅助下仍漏诊了部分恶性肿瘤(虽非高度恶性)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the value of an artificial intelligence (AI) system in assisting radiologists to improve the assessment accuracy of BI-RADS 0 cases in mammograms.

METHODS: We included 34,654 consecutive digital mammography studies, collected between January 2011 and January 2019, among which, 1088 cases from 1010 unique patients with initial BI-RADS 0 assessment who were recalled during 2 years of follow-up were used in this study. Two mid-level radiologists retrospectively re-assessed these BI-RADS 0 cases with the assistance of an AI system developed by us previously. In addition, four entry-level radiologists were split into two groups to cross-read 80 cases with and without the AI. Diagnostic performance was evaluated using the follow-up diagnosis or biopsy results as the reference standard.

RESULTS: Of the 1088 cases, 626 were actually normal (BI-RADS 1 and no recall required). Assisted by the AI system, 351 (56%) and 362 (58%) normal cases were correctly identified by the two mid-level radiologists hence can be avoided for unnecessary follow-ups. However, they would have missed 12 (10 invasive cancers and 2 ductal carcinoma in situ cancers) and 6 (invasive cancers) malignant lesions respectively as a result. These missed lesions were not highly malignant tumors. The inter-rater reliability of entry-level radiologists increased from 0.20 to 0.30 (p < 0.005) by introducing the AI.

CONCLUSION: The AI system can effectively assist mid-level radiologists in reducing unnecessary follow-ups of mammographically indeterminate breast lesions and reducing the benign biopsy rate without missing highly malignant tumors.

KEY POINTS: • The artificial intelligence system could assist mid-level radiologists in effectively reducing unnecessary BI-RADS 0 mammogram recalls and the benign biopsy rate without missing highly malignant tumors. • The artificial intelligence system was capable of detecting low suspicion lesions from heterogeneously and extremely dense breasts that radiologists tended to miss. • The use of an artificial intelligence system may improve the inter-rater reliability and sensitivity, and reduce the reading time of entry-level radiologists in assessing potential lesions in BI-RADS 0 mammograms.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yi C, Tang Y, Ouyang R, et al. The added value of an artificial intelligence system in assisting radiologists on indeterminate BI-RADS 0 mammograms. Eur Radiol. 2021. PMID: 34528107. doi:10.1007/s00330-021-08275-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。