剪切波弹性成像测量的肿瘤硬度与早期乳腺癌无病生存期的关联
该回顾性研究纳入202例新诊断T1-2期浸润性乳腺癌女性,术前接受剪切波弹性成像(SWE),分析SWE特征与无病生存期的关联。中位随访56个月,15例(7.4%)复发;复发者平均弹性值(Emean)显著高于未复发者(184.4 kPa vs 134.9 kPa,p=0.005)。多因素Cox分析显示,Emean>121.7 kPa与更差的无病生存期独立相关(调整HR=10.01,95%CI 1.31-76.33,p=0.026)。
要点
- SWE测量的肿瘤平均弹性值(Emean)升高与早期乳腺癌复发风险增加相关。
- Emean>121.7 kPa时,复发风险显著增高(调整HR=10.01)。
- 脉管侵犯亦为无病生存期的独立危险因素(调整HR=7.72)。
关键影像表现/征象
- 复发患者的平均、最小和最大弹性值均高于未复发患者(184.4、138.3、210.5 kPa vs 134.9、101.7、159.8 kPa;p分别为0.005、0.005、0.012)。
诊断标准与关键数值
- 预测复发的ROC曲线分析显示,Emean的曲线下面积(AUC)最大,为0.717,最佳截断值为121.7 kPa。
- 多因素Cox分析:Emean>121.7 kPa与更差的无病生存期相关(调整HR=10.01;95%CI 1.31-76.33;p=0.026)。
- 脉管侵犯与更差的无病生存期相关(调整HR=7.72;95%CI 1.74-34.26;p=0.007)。
临床应用与阅片要点
- 术前SWE测量的Emean可作为早期乳腺癌无病生存期的潜在定量影像生物标志物,辅助风险分层。
- Emean>121.7 kPa提示复发风险增高,阅片时可关注肿瘤硬度参数并记录。
- 结合脉管侵犯等病理因素综合评估预后。
局限性
- 回顾性研究设计。
- 单中心研究。
- 事件数较少(15例复发),可能影响统计效能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine whether shear-wave elastography (SWE)-measured tumor stiffness is associated with disease-free survival in females with early-stage invasive breast cancer.
METHODS: This retrospective study included 202 consecutive females (mean age, 52.9 years; range, 25-84 years) with newly diagnosed T1-two breast cancer who underwent preoperative SWE between April 2015 and January 2016. Tumor stiffness was assessed and quantitative SWE features of each breast lesion were obtained by a breast radiologist. Cox proportional hazard models were used to identify associations between SWE features and disease-free survival after adjusting for clinicopathologic factors.
RESULTS: Fifteen (7.4%) patients exhibited recurrence after a median follow-up of 56 months. Mean (Emean), minimum, and maximum elasticity values were higher in females with recurrence than in those without recurrence (184.4, 138.3, and 210.5 kPa vs 134.9, 101.7, and 159.8 kPa, respectively; p = 0.005, p = 0.005, and p = 0.012, respectively). Receiver operating characteristics curve analysis for prediction of recurrence showed that Emean yielded the largest area under the curve (0.717) among the quantitative SWE parameters, and the optimal cut-off value was 121.7 kPa. Multivariable Cox proportional hazards analysis revealed that higher Emean (>121.7 kPa) [adjusted hazard ratio (HR), 10.01; 95% CI: 1.31-76.33; p = 0.026] and lymphovascular invasion (adjusted HR, 7.72; 95% CI: 1.74-34.26; p = 0.007) were associated with worse disease-free survival outcomes.
CONCLUSION: Higher SWE-measured Emean was associated with worse disease-free survival in females with early-stage invasive breast cancer.
ADVANCES IN KNOWLEDGE: Tumor stiffness assessed with shear-wave elastography might serve as a quantitative imaging biomarker of disease-free survival in females with T1-two breast cancer.
引用
- Kim JY, Kim JJ, Hwangbo L, et al. Tumor stiffness measured by shear-wave elastography: association with disease-free survival in women with early-stage breast cancer. Br J Radiol. 2021. PMID: 34558307. doi:10.1259/bjr.20210584
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。