文献速递乳腺乳腺X线

基于乳腺X线摄影的影像组学预测乳腺癌复发风险:多中心研究

Mammography-based radiomics for predicting the risk of breast cancer recurrence: a multicenter study.
PubMed 文献 · Br J Radiol · 2021-09-14

本研究回顾性纳入两家医院304例术前有乳腺X线摄影且Oncotype DX评分可用的ER阳性、淋巴结阴性浸润性乳腺癌患者,构建基于影像组学特征和临床因素(肿瘤分级、HER2)的模型预测复发风险。模型在训练集、内部测试集和外部测试集的AUC分别为0.92、0.88和0.84,决策曲线分析显示阈值概率0.1至1.0时模型净获益优于全治或全不治方案。

要点

  • 乳腺X线影像组学联合肿瘤分级和HER2可无创预测ER阳性、淋巴结阴性乳腺癌复发风险。
  • 模型在外部测试集AUC为0.84,具有较好的泛化能力。
  • 决策曲线分析支持模型在阈值概率0.1至1.0范围内临床净获益优于默认策略。

局限性

  • 回顾性研究设计
  • 样本量有限(共304例)
  • 仅纳入两家医院数据

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to establish a mammography-based radiomics model for predicting the risk of estrogen receptor (ER)-positive, lymph node (LN)-negative invasive breast cancer recurrence based on Oncotype DX and validated it by using multicenter data.

METHODS: A total of 304 potentially eligible patients with pre-operative mammography images and available Oncotype DX score were retrospectively enrolled from two hospitals. The patients were grouped as training set (168 patients), internal test set (72 patients), and external test set (64 patients). Radiomics features were extracted from the mammography images of each patient. Spearman correlation analysis, analysis of variance, and least absolute shrinkage and selection operator regression were performed to reduce the redundant features in the training set, and the least absolute shrinkage and selection operator algorithm was used to construct the radiomics signature based on selected features. Multivariate logistic regression was utilized to construct classification models that included radiomics signature and clinical risk factors to predict low vs intermediate and high recurrence risk of ER-positive, LN-negative invasive breast cancer in the training set. The models were evaluated with the receiver operating characteristic curve in the training set. The internal and external test sets were used to confirm the discriminatory power of the models. The clinical usefulness was evaluated by using decision curve analysis.

RESULTS: The radiomics signature consisting of three radiomics features achieved favorable prediction performance. The multivariate logistic regression model including radiomics signature and clinical risk factors (tumor grade and HER 2) showed good performance with areas under the curve of 0.92 (95% confidence interval [CI] 0.86 to 0.97), 0.88 (95% CI 0.75 to 1.00), and 0.84 (95% CI 0.69 to 0.99) in the training, internal and external test sets, respectively. The DCA indicated that when the threshold probability is ranges from 0.1 to 1.0, the radiomics model adds more net benefit than the "treat all" or "treat none" scheme in internal and external test sets.

CONCLUSION: As a non-invasive pre-operative prediction tool, the mammography-based radiomics model incorporating radiomics and clinical factors show favorable predictive performance for predicting the risk of ER-positive, LN-negative invasive breast cancer recurrence based on Oncotype DX.

ADVANCES IN KNOWLEDGE: The mammography-based radiomics model incorporating radiomics and clinical factors shows favorable predictive performance for predicting the risk of ER-positive, LN-negative invasive breast cancer recurrence.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Mao N, Yin P, Zhang H, et al. Mammography-based radiomics for predicting the risk of breast cancer recurrence: a multicenter study. Br J Radiol. 2021. PMID: 34520235. doi:10.1259/bjr.20210348

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。