文献速递妇产影像US

孕中期早产筛查中的期望值偏倚

Expected-value bias in mid-trimester preterm birth screening.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-01-01

该研究在西班牙单中心评估孕中期宫颈长度测量是否受观察者偏倚影响,采用盲法测量两个月并与前期非盲法对照。结果盲法组短宫颈患病率5.5%,非盲法组2.7%(P=0.024),盲法组宫颈长度分布正常而非盲法组偏斜。结论认为期望值偏倚存在,盲法可提高筛查性能。

要点

  • 孕中期宫颈长度测量存在期望值偏倚,非盲法可能低估短宫颈患病率。
  • 盲法测量可使宫颈长度分布更接近正态,减少偏倚。
  • 日常筛查中建议对宫颈长度测量采用盲法策略。

关键影像表现/征象

  • 盲法组宫颈长度分布正常,非盲法组呈偏斜分布。
  • 盲法组短宫颈患病率5.5%,非盲法组2.7%(P=0.024)。
  • 宫颈长度24-25 mm发生率盲法组2.4%,非盲法组0.6%(P<0.005)。

诊断标准与关键数值

  • 短宫颈定义为孕中期超声宫颈长度≤25 mm。
  • 盲法组短宫颈患病率5.5%,非盲法组2.7%,P=0.024。
  • 宫颈长度24-25 mm发生率盲法组2.4%,非盲法组0.6%,P<0.005。

临床应用与阅片要点

  • 测量宫颈长度时建议采用盲法,避免因期望值导致测量偏倚。
  • 非盲法可能低估短宫颈患病率,影响早产风险分层。
  • 注意宫颈长度24-25 mm临界值的测量变异。

局限性

  • 单中心研究,样本量有限。
  • 盲法组与对照组非同期,可能存在时间偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Cervical length (CL) measurement ≤ 25 mm on mid-trimester ultrasound scan is a known risk factor for preterm birth, for which vaginal progesterone is recommended. The aims of this study were to evaluate whether CL measurement is affected by observer bias and to assess the impact on short cervix prevalence of masking CL measurement during routine mid-trimester ultrasound scan.

METHODS: This was a flash study designed for a 2-month period (October and November 2018) at Cruces University Hospital (Bizkaia, Spain), in which all CL measurements from routine mid-trimester scans were masked. During the study period, there was no modification of the routine screening method, and women with a short cervix were prescribed 200 mg vaginal progesterone daily as per usual. The control group included women examined in a 2-month period (April and May 2018) prior to the study, in which CL measurements were taken as usual by a non-blinded operator. The primary outcome was the prevalence of short cervix in each group.

RESULTS: A total of 983 CL measurements were analyzed, including 457 in the blinded group and 526 in the control group. The prevalence of short cervix was 2.7% in the non-blinded group and 5.5% in the blinded group (P = 0.024). We identified a statistically significant difference in the incidence of CL of 24-25 mm between the two groups, with a lower prevalence in the non-blinded vs blinded group (0.6% vs 2.4%; P < 0.005). Moreover, the distribution of CL values was normal in the blinded group, in contrast to the non-blinded group, which was characterized by skewed distribution of CL values.

CONCLUSIONS: Expected-value bias exists and should be taken into account when measuring CL in mid-trimester preterm birth screening. Blinding has demonstrated to be an effective strategy to improve the performance of CL screening in clinical practice. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Aiartzaguena A, Del Campo A, Melchor I, et al. Expected-value bias in mid-trimester preterm birth screening. Ultrasound Obstet Gynecol. 2022. PMID: 34542928. doi:10.1002/uog.24778

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。