文献速递腹部泌尿生殖外周血管MRCT

3.0T非增强MR血管成像对活体肾移植供者肾血管的一站式术前评估:与CTA及手术结果对比

One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results.
PubMed 文献 · Br J Radiol · 2021-10-05

本研究纳入30例活体肾供者,术前均行CTA和3.0T NCE-MRA,由两名放射科医师独立评估肾动静脉解剖及潜在肾脏病变,并与手术结果对照。结果显示NCE-MRA与CTA在肾动静脉分支评分上无显著差异,SNR和CNR更高,对正常肾动脉、早期分支及肾静脉解剖变异的显示与术中诊断一致性良好。结论认为3.0T NCE-MRA可用于活体供肾术前血管评估。

要点

  • 3.0T NCE-MRA可准确评估肾动静脉解剖及变异,与手术结果一致性良好。
  • NCE-MRA图像SNR和CNR高于CTA,肾血管分支评分与CTA无显著差异。
  • NCE-MRA测量血管直径较CTA偏小,但长度测量无显著差异。

核心结论

  • 3.0T NCE-MRA可用于评估主肾动静脉,对解剖和变异分类具有高准确性,适用于活体供肾术前血管评估。

研究设计与样本

  • 前瞻性研究纳入30例肾供者,术前均行CTA和3.0T NCE-MRA,以手术结果为参考标准。
  • 两名放射科医师独立评估肾动静脉解剖及潜在肾脏病变,采用κ检验评估一致性。

关键影像表现/征象

  • NCE-MRA与CTA对肾动静脉分支的评分无显著差异(p > 0.05)。
  • NCE-MRA的肾血管SNR和CNR高于CTA(p < 0.001)。
  • NCE-MRA测量肾血管直径小于CTA(p < 0.05),长度测量无显著差异(p > 0.05)。
  • 两种方法对正常肾动脉及早期分支的显示与术中结果一致。
  • 两种方法对肾静脉解剖变异的判断与术中诊断一致性良好(p < 0.001)。

诊断标准与关键数值

  • 两名放射科医师对NCE-MRA肾动静脉图像质量评分高度一致(p < 0.001)。

临床应用与阅片要点

  • 3.0T NCE-MRA可作为活体供肾术前无对比剂血管评估的替代方法。
  • 阅片时注意NCE-MRA测量血管直径较CTA偏小,报告时应结合临床。

局限性

  • 样本量较小(30例),单中心研究设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The study was to investigate the feasibility and accuracy of assessment for living renal donors before transplantation by using 3.0 T non-contrast-enhanced magnetic resonance angiography (NCE-MRA).

METHODS: 30 renal donors were investigated and underwent computed tomography angiography (CTA) and 3.0 T NCE-MRA before nephrectomy. Two radiologists independently assessed arterial and venous anatomy and potential kidney lesions. The image quality score, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diameters and lengths of renal arteries and veins were compared between CTA and NCE-MRA. Imaging findings were compared with the surgical results served as reference standard. Agreement was assessed using κ test. The Wilcoxon test and paired sample t test were used for statistically significant differences.

RESULTS: The results of image quality score for renal arteries and veins were highly consistent between the two radiologists in NCE-MRA (p < 0.001). There was no significant difference in the scores of renal arterial and venous branches between NCE-MRA and CTA (p > 0.05). The SNR and CNR of renal vessels were higher than CTA (p < 0.001). There were no statistically significant differences in the length of renal vessels measured by the two methods (p > 0.05), and the diameter was smaller than that of CTA (p < 0.05). The detection of normal renal arteries and early branches by both examination techniques was consistent with intraoperative findings. Both methods showed good consistency between the anatomical variation of renal vein and the intraoperative diagnosis (p < 0.001).

CONCLUSION: 3.0 T NCE-MRA can be used for evaluation of main renal arteries and veins with high accuracy for anatomy and variation classification, and can be used for pre-operative vascular evaluation of living donor kidney transplantation.

ADVANCES IN KNOWLEDGE: 3.0 T NCE-MRA can be used for evaluation of main renal arteries and veins with high accuracy for anatomy and variation classification, and can be used for pre-operative vascular evaluation of living donor kidney transplantation.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Li X, Xia F, Chen L, et al. One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results. Br J Radiol. 2021. PMID: 34558306. doi:10.1259/bjr.20210589

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。